My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20570
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20570
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:51:21 AM
Creation date
6/4/2019 7:51:19 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20570
Building Department - Name
DR HORTON INC
Address
6878 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Date: <br /> wrightsoft- Entire House By: <br /> Progressive Air Systems, Inc Plan: Cali 1828 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> ■ • • • <br /> For: DR Horton <br /> Lot 14 Blk 11 Silverado, Zephyrhills, FL <br /> Notes: <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17539 Btuh, Structure 16295 Btuh <br /> Ducts 3561 Btuh Ducts 4598 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 21100 Btuh Use manufacturer's data <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 20893 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2360 Btuh <br /> Ducts 606 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Coolingg (none) <br /> Area(ft2 1820 1820 Equipment latent load 2966 Btuh <br /> Volume(ft3) 16012 16012 <br /> Air changes/hour 0.26 0.14 Equipment total load 23859 Btuh <br /> Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO30 Cond CH14NBO30 <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual airflow 1000 cfm <br /> Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=32 OF <br /> Backup: <br /> Input=7 kW, Output=22477 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> t - - wrigfrtsoft' 2018-Nov-06 15:33:26 <br /> �— Right-Suite®Universal 2017 17.0.21 RSU25554 14CCN ...ightsoft Files\Express horn Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.