Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of.8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be:graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru'the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met: <br /> 7. All.property markers shall be uncovered and marked at tim_ e of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing, meclianical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302,6 of the F.B.C. (Fire Separation). <br /> 11..Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4:of the F.B.0 <br /> 12. Water heaters shall comply with section P667.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2,F.B.C. <br /> 19. Combination-type AFCI breakers are Irequired at all.locations requiring an AFCI type breaker: <br /> 20. Carbon moii6xide alarms will be required in new construction that uses f 3ssil-6urniiig heating. <br /> or appliances or an attached garage: They shall be installed in accordance with the F.B.C. <br /> .. <br /> I. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N:E.C, Codes will be eriforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.1 1 of the 2016 N:E:C <br /> 24. In accordance with the Land Development Code, lots shall be.sodded before final.at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A conv of the energ±ekels shall be with yern:it at all times <br /> 27.. Cotiy of final insulation report shall be..provided with.permit before.fnab <br /> M.No fence,.nool or screen enelosure is.issued with this eermit.- <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />