Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E..shall be a minimum of:8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be.graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction fest required.if,24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.M. use permit. All 4 sides of driveway thiu the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met: <br /> 7. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8, All A:D.A. requirements shall be met. <br /> 9: No electric, plumbing,mechanical; or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302,6 of the F.B.C. (Fire-Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage.unless <br /> protected by-approved barriers. M303.4 of the F.B.0 <br /> 12. Water.heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade, M13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors'are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All.glazing requirements are to be in accordance with R..308.4.of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18: "Green gypsum board"shall riot be used as a backer in showers or tubs,R702.4:2:F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locatio1.ns requiring an AFCI type breaker. <br /> 20. Carbon-monoxide alarms will be required in new construction that uses fossil,burning heating <br /> or appliances or an attached garage: They shall be;installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit W.unit- This includes all <br /> underground plumbing and electric. <br /> 22. All 2616 N.E.C. Codes will be enforced. <br /> 23.Tamper=Resistant Receptacles in accordance with 406.11-of the 2016 N:E.0 <br /> 24. In accordance with the Land Development Code, lots shall be-sodded before final at least 10 <br /> feet around the structure: <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26.A copy of the enerky cacls shall be'with permit at all times <br /> 27 Copy.of final insulation r-epori shall be provided with permit before.final <br /> 28:No fence.:pool or screen enclosure -is.issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A:-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />