Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum-of8 above the road elevation and an engineered site plan. <br /> 2. Lots shall be.graded to comply with R40.1.3 of the F.B.C. <br /> 3. Compaction test required if 24"'or.more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A.requirements shall be met. <br /> 9. No.electric,-plumbing, mechanical, or framing shall be covered without an.inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302..6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> piotected by approved barriers. M303.4.of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13.- Foundation supports for A/C units shall be raised at least 3"above finished_ grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be 'installed in accordance with R313.1 of the.F.B.C. <br /> 16: Ali glazing requirements are to be in accordance with R..308.4,of the F.B.C. <br /> 17. All means.of egress are to.be in accordance with R311 of the F.B.C.- <br /> 18. "Green gypsum board'-' shall riot be used as a backer,in showers or tubs. R702.4.2 F.B,C. <br /> 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker: <br /> 20. Carbon.monoxide alarms will be required in new construction that uses fossil:burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B;C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to.unit. This includes all . <br /> underground plumbing and electric: <br /> 22. All 2016 N.E.C: Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N:E.0 <br /> 24. In accordance with.the Land Development Code, lots shall be sodded before final.at least 10. <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 27 Cony.of fin-di insulation report shall be Provided ivith Permit before.rinaL <br /> 28:No fence;:pool or screen-enclosure &issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />