Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8 above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required.if_24" or,more of fill dirt is brought in at any one place. <br /> 4, Tie in survey require..before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be.met. <br /> 7. All.property markers shall be uncovered and marked at time of.first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing,mechanical, or framing shall be.covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C..(Fire Separation). <br /> 11. Appliances shall not be installed in a location where sojectto mechanical damage unless <br /> protected byapproved barriers. M303.4.of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.R.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. 'M1620'.4 <br /> 15. Smoke detectors are to be installed in accordance with R313..1 of the:F.B.C. <br /> 16: Ali glazing-requirements are to be in accordance with R308A of the F.B.C. <br /> 17. All means of egress are to be in,accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall riot be used as a baeker.in showers or tubs. R702.4.2 F.B.C. <br /> .19. Combination-type AFCI breakers are.required at all locations requiring an AFCI type breaker: <br /> 20. Carbon monoxide alarms:will be required in new construction that uses fossil=burning heating <br /> or appliances or an attached garage_: They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit W.unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.-E.C: Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.-C <br /> 24: In accordance with the Land Development Code, lots shall be,sodded before final at least 10 . . <br /> feet around the structure. - <br /> 25.Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A copy of the energy cacls shall be with nern:it at all times. <br /> 27.. Copy of final insulation reportshall be.:provided with'permit before.final <br /> 28.No fence.,pool or screen enclosure is.issued with this nermft. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />