REV. REVISIONS: lEvISED BY DATE: <br /> MODEL DESIGNATION: Simonton Series 06-05 2—Panel Vinyl Patio Door NO P.E. SEAL REQUIRED r <br /> MAXIMUM OVERALL NOMINAL SIZE: See Size Chart INSTALLATION SUPPORTED 2 UPDATED NOTES,GENERAL DESCRIPTION,AND T.D.D. 04/Oe/n <br /> BY AAMA TEST REPORTS 3 ADDED S12ES PER NEW TESTING. T.D.D. 05/04/11 <br /> f)FSIGN PRESSURE RATING: See Size Chart 010 X 2 1/2-MIN. WOOD 4 ADDED GLAZING DETAILS. T.D.O. 06/20/11 <br /> USABLE CONFIGURATIONS, X0, OX SCREW WITH 1.50'MIN. 6 ADDED GLAZING NOTE AND UPDATED SIZE T.D.D. 03/11/13 <br /> EMBEDMENT INTO WOOD 2X BUFCK <br /> MIN.EDGE DIST., SEE NOTES B ADDED MIN.EDGE DIST.NOTE B.J.S.. 06/17/15 <br /> GENERAL DESCRIPTION; The head, sill, and side Jambs are extruded PVC. The wall thickness 7 UPDATED SIZE CHART&ANCHOR SPACING LMH 11/23/15 <br /> through which the anchor screw penetrates Is a minimum of 0.070". SILICONE CAULK <br /> SEE NOTES 11 &12 <br /> 1/4'MAX. SHIM SILICONE CAULK <br /> _ SEE NOTES 11 do 12 <br /> 6-�I 3..—I 3 6"1 S4 REQUIRED SHIM <br /> SIUCONE CAULK <br /> / SEE NOTES 11 h 12 <br /> 0 SILICONE <br /> SEE NOTES I &CAULK <br /> HEAD J <br /> 2x eucl< <br /> SILL <br /> I , <br /> i <br /> 2%BUCK SILICONE CAULK <br /> SEE NOTES 11 &12 SILICONE CAULK <br /> 7Zj I 1/4'MAX. SHIM SEE NOTES 11 h 12 2X BUCK <br /> 1/4-MAX.SHIM yB X 2 1/2' WOOD <br /> yB%2 1/2"MIN. y10%2 1/2'MIN. WOOD SCREW THROUGH KEEPER <br /> ¢ WOOD SCREW, SCREW WITH 1.50"MIN. INTO WOOD <br /> KEEPER TO BUCK MAX EMBEDMENT INTO WOOD <br /> f MIN. EDGE DIST., SEE NOTES <br /> a I O.C. SPACING y10 X 2 1/2"MIN. WOOD <br /> g SEE SIZE CHART SCREW WITH 1.50'MIN. <br /> WOOD <br /> O 0 X; �- MIN.EDGE DISTEMBEDMEN.,SEE NOTES <br /> SILICONE CAULK <br /> I SEE NOTES 11 k 12 <br /> I I <br /> � I <br /> _ �1FIXED PANEL JAMB SILICONE CAULK <br /> SEE NOTES 11 do 12 <br /> KEEPER JAMB <br /> NOTES: <br /> ' 1.This Installation has been evaluated for use in locations adhering to the Texas 8 Florida Building Codes and where pressure requirements as determined by ASCE 7 Minimum <br /> Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein,for use outside the H.V.H.Z. <br /> 2.All exterior perimeter surfaces of the door must be caulked.Interior caulking is optional unless noted otherwise. <br /> 3.Anchors shall be specified and spaced as shown.Anchor embedment to base material shall be beyond wall dressing or stucco and Into wood. <br /> / 4.The responsibility for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safely requirements rests solely with the architect, <br /> owner,or contractor.Shims ` <br /> 6.Shims are optional.Maximum shim stack is tlo", <br /> 6.Wood bucks(by others)must be engineered and anchored properly to transfer loads to the structure. <br /> UNIT WIDTH 7.When used In areas requiring Impact protection,this product REQUIRES the use of approved Impact resistant shutters of other external protection. <br /> S.Flashing should be applied using the ASTM E 2112 method appropriate for the opening Into which the door Is being Installed. <br /> "W" MAX. OVERALL FRAME WIDTH 9.Installation anchors should be at least 3/4'from the edge of the wood. <br /> 10.Glazing shall comply with ASTM E 1300 and safety glazing requirements per Florida Building Code section 2406. <br /> 11.Use 100%pure silicon caulk. Make sure surfaces are completely free from all old caulk,damaged wood,wood fibers,grease,all din,rust,mold or similar contaminants. <br /> Vacuum opening surfaces completely.A fully primed surface Is recommended,but not required.Cleaning of all surfaces should be done the same day of which the silicone <br /> caulk Is to applied.For more details see"New Construction Installation Inslructlons"on Simonlon.com. <br /> SIZE CHART 12.Caulk application:recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all contact surfaces are clean antl dry <br /> OVERALL SIZE 0 C, Including the new wlndow(s). Use a backer rod on all joints-314'deep and/or wider than 1/4". Finished caulk joint should be a minimum of 3/8"deep and make full contact <br /> SPACING DP RATING with both the new window and structural opening surfaces.Silicone caulk should be forced Into joint or compressed to assure full contact on both surfaces and to expel any air <br /> 71" 96' 17, packets. <br /> 95' BO' 23' f35PSF DISCI <br /> OSIRFSTATEMN7 Fl S SIMONTON' B: IN0412' 7 <br /> 71" 80' on Windows <br /> 23' This document le the property of Simonton which Dimensional Tolerances t <br /> 71" 1 60" 1 23" 50 PSF 'steins o11 proprietary and other righle to Its subject matter. Untess Otherwise Soac)fll,d T!7 I� I N n o w s DRAWN <br /> • 04/10/g9 <br /> This doeumanl t9 provided to the feelplant an the expressed 0 h TE PE 1 Cn0,—Avenue ,CHECKEa eY:OAIE: <br /> CIRCLED ANCHORS REQUIRED ONLY FOR condition that ll is of to hw dieelosed,reproduced In whole or Penns6ura,WV 2fi415 <br /> g5xBO AND 7lxBD-DP35. part.nor used In conjunction with the design,manufacture or Decimals Angles <br /> • repair of goods for anyone other than Simonton window SCALE: SHEET: APPR D BY; DATE: <br /> without Its co-neent. This rostrietlon does not IImII the X:k 03 FIT 1 of 1 <br /> recipient's rights to utilize Information contained In this SURFACE AREA: SERIES: <br /> document which Is Properly obtained from another source. xx t Ol 0' 30 min. 06-05 2-PANEL PATIO DOOR <br /> INISH TREATMENT: .XXX f .005 <br /> 11TLE: <br /> FILE:IND412 2X BUCK RE7ROFlT INSTALLATION(AS TESTED) <br />