My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21028
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21028
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 8:20:09 AM
Creation date
6/4/2019 8:20:09 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS VILLAGE
Building Department - Doc Type
Permit
Permit #
19-21028
Building Department - Name
ASHINGTON MANAGEMENT LLC
Address
6215 ABBOTT STATION UNIT 102
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L.Series Specifications <br /> Architect/Engineer Specifications <br /> General <br /> L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box,4 x 4 x 1'/.—inch back box,4=inch <br /> octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal <br /> mounting,plate shall be used for mounting ceiling and wall products for all standard models and a,separate universal mounting plate shall be <br /> used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also, L-Series <br /> products,when used with the SyncsCircuit-Module accessory,shall be powered from a non-coded•notification appliance circuit output <br /> and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs <br /> shall operate between 8.5 and 17.5 volts;24-volt-rated notificatioh appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor <br /> L=Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered•power supply. <br /> Strobes and horn strobes shall have field-selectable candela settings including 16,30,75,95;110,135,and 185: <br /> Strobe <br /> The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe <br /> shall be wired as a primary.-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible <br /> signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and <br /> associated lens/reflector system. <br /> Horn Strobe Combination <br /> The horn strobe shall be a System Sensor L-Series Model. listed to UL 1971 and UL 464 and shall.be approved for fire protective <br /> service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act <br /> requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist <br /> of a xenon flash,tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a <br /> temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe . <br /> models shall operate on a coded or non-coded power supply. <br /> Synchroniiation Module <br /> The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module <br /> shall synchronize SpeotrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns <br /> on horn strobe models over a single pair.of wires.The module shall mount to a 41 V16 x.411/16 x 21/8-inch.back box,The module shall also <br /> control two-Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more <br /> synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded powersupply. <br /> Standard Operating Temperature 32'F to 120°F(0'C to 49°C) <br /> Humidify Range: 10 to 931/6 non-condensing <br /> Strobe Flash Rate 1 flash per second <br /> NominA.Voltage Regulated.12 DC or regulated 24 DC/FWR'•? <br /> Operating Voltage Range 6 to 17.5.V(12 V nominal)or 1'6 to 33 V(24.V nominal) <br /> 'Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) . <br /> 'Input Terminal Wire Gauge 12 to 18 AWG <br /> Wall-Mount Dimensions(including lens) 5.6-L x 4.7"W x 1.91"D.(143 mm L x 119 mm W k 49 mm D) <br /> Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46' W x 1:91"D(133 mm L x 88.mm W x 49 mm D) <br /> 'Horn Dimensions 5.6-L x 4.7"W z.1.25`D(143 trim L x.119 mm.W x,32 mm D) <br /> Compact Horn Dimensions. .5.25"'L x 3.45"W x 1.25".D(133mm L x 88mm W x 32mm D):- - <br /> 1.Full Wave Rectified(FWR)voltage is a non-regulated;time-varying power source that is.used on some power supply and panel outputs. <br /> 2:Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. <br />
The URL can be used to link to this page
Your browser does not support the video tag.