Laserfiche WebLink
Data Sheet 2106 T" <br /> AsB_�u � tt <br /> Engineered Systems <br /> - - <br /> Discove PhotoelectricP <br /> Detector �. <br /> • DISC-P - - r <br /> 0_eserip-tion <br /> The AsBuilt intelligent analog addressable photoelectric detector(DISC-P) <br /> operates seamlessly with the AsBuilt IP Fire SeriesTm network fire control. <br /> The DISC-P communicates to and is managed and controlled by the IPF <br /> SeriesTm analog loop module(ALM). <br /> The Disc-P is physically distinguished from the Discovery ionization IF.eatures <br /> detector(DISC-])by the clear colored dual LED's.The LED's light steady <br /> when in an alarm condition and flash briefly when polled by the ALM.The Improved detection capabilities with <br /> dual LED's provide for 360 degree visibility. smoldering,smoky fires <br /> • Discovery detectors distribute <br /> O eration intelligence across the installed <br /> system <br /> The DISC-P constantly monitors its sensing chamber and its internal e Patented infrared smoke sensing <br /> electronics utilizing a patented smoke chamber and infrared smoke design <br /> sensing design. . Sleek,non-fading white polycarboriate <br /> An infrared light emitting diode with its collimator is arranged at an obtuse enclosureZero insertion force base <br /> angle to the photo-diode.The photo-diode has an integral daylight <br /> blocking filter.The IR LED emits a burst of collimated light every second. i 5 user selectable modes <br /> In clear air the photo-diode receives no light directly from the IR LED 0 Powerful transient rejection algorithms <br /> because of the angular arrangement and the chamber baffles.When 0 Conventional device mode <br /> smoke enters the chamber it scatters light from the emitter IR LED onto . Patented XPertprogramming card <br /> the photo-diode in an amount-related to the smoke characteristics and eliminates addressing errors during <br /> density.The photo-diode signal is processed to provide an analog value <br /> for transmission when the detector is interrogated by the ALM. system installation and maintenance <br /> • Alarm flag sends signal to system <br /> Upon crossing the alarm threshold the detector will make the even when device is not being <br /> determination that an alarm condition exists and send a signal to the ALM interrogated <br /> that interrupts the normal polling process to signal the alarm condition. 9 Wide variety of addressable <br /> The ALM puts the changed state on the IP network and all outputs input/output devices <br /> associated with the specific detector are activated. 0 Relay and synchronized temporal <br /> sounderbases <br /> The DISC-P manages its own automatic drift compensation thereby 0 Green/RoHS Compliant <br /> accelerating overall system performance by offloading the management of <br /> the device compensation values from the ALM to the DISC-P. <br /> Compensation is made to adjust the detector for the infiltration and Listings <br /> accumulation of dirt and dust over time.By compensating the detector <br /> alarm thresholds the sensing window is adjusted to remain at original UL File: S5022 <br /> factory specifications. CSFM:7272-1394:118 <br /> MEA:294-95-E-4 <br /> Like all Discovery devices,the DISC-P has five pre-programmed user <br /> settings that may be accessed and changed from the IPF Series network <br /> control.Further,the pre-programmed settings are utilized in establishing <br /> the automatic sensitivity values in place with the IPF Day/Night sensitivity <br /> programming. <br /> Product Data Sheet Number Rev/Revision Date = = = <br /> IPF.SeriesTm Detectors DISC-P 2106 1.4/10/1/2009 P.FIRESERIES', <br /> ©Copyright 2008 AsBullt Engineered Systems,Inc. <br />