Engineer-Specification <br /> The contractor shall.furnish.and install,where indicated on the plans,individually identifiable manual pull stations <br /> connected to the Fire Alarm control.The pull stations shall be monitored for device identification,alarm reporting and. <br /> trouble supervision.The pull station shall be capable of reporting to the fire alarm control and storing in.the history log <br /> activation,trouble and reset information.The single-action and double action stations shall consist of a die-cast metal <br /> alloy housing fitted with a pull out lever which,when operated, locks in position after activating <br /> an alarm initiating contact.The double-action station shall also contain an additional lever which requires depression <br /> in order to reach the pull out lever. Pull station shall utilize gold plated contacts to minimize the risk of corrosion. Pull <br /> Stations shall be key-resettable and shall be compliant with the Americans with Disabilities Act(ADA).The <br /> addressable interface device must be UL listed and UL listed as compatible with the AsBuilt IP Fire SeriesTm network <br /> 'fire controls.The manual stations shall be As Built Engineered Systems part numbers AB-42SK2(single action),and <br /> AB-42SK1 (double action). <br /> Technical Data <br /> Listings: UL, ULc, FM,CSFM, MEA <br /> Temperature: -400 to 1500F,90%relative humidity @ 1000F <br /> Switch Rating: <br /> SG-32-Micro switch 1 Amp @ 30 VDC, 1Amp-@ 125 VAC <br /> SG-42-.Toggle switch 2 Amps @ 125 VDC,2 Amps @ 240 VAC <br /> Weight: _ 1.2lbs <br /> Dimensions: 4 3/4"h x 3 1/4"w x 1.1"d <br /> Surface-Mount Backbox Dimensions: <br /> 4 3/4"h x 3 1/4"w x 2 1/4"d(outside);2 1/8"d(inside)cast and sheet metal <br /> Deep Surface-Mount Backbox Dimensions: <br /> 4 3/4"h x 31/4"w x 2 3/4"d <br /> Ordering.I nformation <br /> Part Number Data Sheet Description <br /> A1342SK2 5000 Single Action Pull Station, Key Reset, Red <br /> AB-42SK1 5000 Double Action Pull Station, Key-Reset, Red <br /> AB-42SK2-NY 5000 Single Action Pull Station, Key.Reset, Red—New York City <br /> AB-42SK1-NY 5000 Double Action Pull Station, Key.Reset, Red- New York City <br /> Related Modules <br /> SGB-32S Interior, red,surface mount,sheet metal backbox with 3/4"knockouts <br /> SGB-32SD Deep-Interior,red,surface mount,sheet metal backbox with 3/.4"knockouts <br /> SG-WP Weatherproof, red,surface mount,die-cast metal backbox with one tapped hole for 3/4" <br /> NPT fitting(same as SGB-32C) <br /> SGB-32CD Deep Weatherproof, red,surface mount, die-cast metal backbox with one tapped hole for <br /> 3/4"NPT fitting <br /> SG-GR01 12 pack of scored,plastic(acrylic)break-rods for spares or replacement <br /> Related.Data Sheets <br /> Discovery Detectors: DISC-P,2106;DISC-I,2107;DISC-T,2108;DISC-M,2109 <br /> XP Detectors:XP-P,2101;XP-I,2102;XP-T,21.03;XP-M,2104 <br /> Addressable Base Options:All Bases,2310 <br /> Addressable Devices: DXP-PIM/MPIM, DXP-PID/MPID,2810;DXP-IOM,2812; DXP-SDR,2814,DXP-2PID,2816; <br /> DXP-OCR,2818 <br /> Product.Name. Data Sheet Number Rev/Revision.Date <br /> IPF.SeriesTm Pull Stations 5000 1.0/7/1/2009 iP FIRE sewEs7 <br /> As Built Engineered Systems,Inc. Phone: (508)788-8333 �. - T.� <br /> 1451 Concord Street Fax: (508)788-8334 � ' I <br /> Framingham, MA 01701-7782 Contact:info(cDasbuiltes.com <br /> USA Visit: www.asbuiltes:com Engineered Systems <br /> ©Copyright 2008 AsBuilt Engineered Systems,Inc. <br />