Laserfiche WebLink
v <br /> FLORIDA ENERGY EFFICIENCY CODE <br /> FOR BUILDING CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: SILVERADO Builder Name: D R HORTON <br /> Street: 6757 Wagon Trail St Permit Office: <br /> City,State,Zip: Zephyrhills,FL 33541 Permit Number: <br /> Design Location: 6757 Wagon Trail St(Lot 1) Jurisdiction: <br /> Cond.Floor Area: 1571 Cond.Volume: 15759 <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regression Data: <br /> C: n: R: <br /> CFM(50): 1506 <br /> Single or Multi Point Test Data <br /> ELA: 83 <br /> HOUSE PRESSURE FLOW: <br /> EgLA: 196 <br /> 1 50 Pa 1506 cfm <br /> ACH: 5.73 <br /> 2 0 Pa 0 cfm <br /> SLA: .05 <br /> 3 0 Pa 0 cfm <br /> ACH(50)': 5.73 <br /> 4 0 Pa 0 cfm <br /> 'For prescriptive projects,tested leakage must be <br /> 5 0 Pa 0 cfm ­7 ACH(50). For performance projects, tested <br /> leakage must be —the ACH(50) shown on Form <br /> 6 Pa cfm R405-2017 for this project. <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate <br /> Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by-either individuals as <br /> defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written <br /> report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after <br /> creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> I hereby certify that the above envelope leakage performance results <br /> demonstrate compliance with Florida Energy Code requirements in <br /> accordance with Section R402.4.1.2. <br /> Testing shall be conducted by either individuals as <br /> defined in Section 553.993(5)or(7),Florida Statutes p4 fBEar'1TF <br /> or individuals licensed as set forth in Section V r a O� <br /> 489.105(3)(f),(g),or(1)or an approved third party.A <br /> written report of the results of the test shall be ¢ it <br /> Digitally signed by David Burch <br /> signed by the third party conducting the test and —a� a <br /> 4aia <br /> [ „ / Date:avid Burch, <br /> O=To B EDT Provided to the code official. <br /> IL`L�y,►',i,'�"/'• CN=David Burch,O=TopBuild <br /> Home Services,OU, �'pD. •{4v <br /> EMAILADDRESS=David.Burch <br /> Signature: <br /> @topbuild.com,C=US <br /> David Burch BUILDING OFFICIA <br /> Printed Name: <br /> Date: 04/08/2019 DATE: <br /> Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. <br /> 10/25/2017 426827 <br />