Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8 above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test_required if'24"or more of fill dirt is brought in at any one place. <br /> 4, Tie in survey required before pouring concrete. <br /> 5. Driveways require a.-R:O..W. use permit. All 4:sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7. All prop erty.markers shall be.uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric,'plumbing, mechanical; or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with-section R302,6 of the F.B.C..(Fire Separation). <br /> I L Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4:of the F.B.0 <br /> 12. Water.heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade, M13:08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be'installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4.of the F.B.C-. <br /> 17. All means;of egress are to be in accordance with R311 of the RB.C. <br /> 18: "Green gypsum board"shall not be used as a backer.in:showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are'required at all locations requirin 'an AFCI type breaker: <br /> 20. Carbon.monoxide alarms will be required in new construction that uses fossil=burning heating. <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C.: Codes will be enforced. <br /> 23. Tamper=Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C. <br /> 24: In accordance with the.Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25.Blower door test and blown in insulation card shall be provided before C.O. <br /> 26. A cony of the energy cacls shall be with permit at all times <br /> 27.. Copy of findl insulation report shall beyrovided ivith.perinit before.fin" <br /> 28.No fence,pboll or screen enclosure isIssued with this permik <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />