My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20515
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20515
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 8:00:20 AM
Creation date
6/5/2019 8:00:19 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20515
Building Department - Name
LENNAR HOMES LLC
Address
39555 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Construction Services(BCS) <br /> P-A S C ,, <br /> -rY FLORID COUN N <br /> 011-4'MA% 1:>. I PLAt-I Blower Door Test Report Form <br /> Propoly Add,ow Unit N., <br /> 07- VIC <br /> Permit 1$: Zv. t-ling Company Names C <br /> _ <br /> - - V-.>i - ------- ---- * Z� (,1s4-,,q <br /> Test Vate; eerierNamp: <br /> (C,3 <br /> Tevto,Ced N! Contact Mono' • <br /> ca 3+K0 <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing sh.111 be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by <br /> the Suflding official.testing shall be conducted by in approved third party.A written report of the results of the test <br /> shall be sivned by the party conducting the test(including Agency Name)and provided to the Building Official prior <br /> to Cenificate of Occupancy issuance, Testing shrill be performed at any time alter creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> During testing;(check to verify condition met) <br /> t Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> U'Dampers including exhaust,Intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> I Intended infiltration <br /> 2njerior doors,if installed at the time of the test,shall be open <br /> Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> dHeating and cooling systems,if in I stalled at the time of the test,shall be turned off <br /> U(Supply and return registers,if Installed at the time of the test,shall be fully open <br /> Vb Building volume(W) <br /> Qio Airflow at 50 Pascal(CFM) <br /> AC)ho Air changes per hour at 50 Pascal <br /> Qjo x 60�Vb = - -+.q q ACfl5o(3.0ACH minimum) <br /> Pass Fail M <br /> Out ide Air rrrechanically introduced to space(Icss than 3.0 AC II) <br /> Ih hereby the iiihot, envelope itettki t qe perfin-nitince res tilts dentonstr(tte Compliance <br /> ry, <br /> ,�11`e <br /> C -corthince It Section R407 f.1.wit on ergo C V nirememv in tic,1411 ,0 — -, ,C'� <br /> a3k8 <br /> S ature of Tester Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.