My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18702
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18702
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:07:10 AM
Creation date
9/18/2019 8:26:42 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HELATH SYSTEM
Building Department - Doc Type
Permit
Permit #
17-18702
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIEMENS Fire Safety <br /> NATIONAL FIRE ALARM CODE PAGE 3 <br /> 6. Alarm Notification Appliances and Circuits <br /> Quantity&Style(See NFPA 72,Table 3-7)of notification appliance circuits: 2N <br /> Types and quantities of alarm indicating appliances installed: 0 Quantity of NAC power extenders <br /> a) 0 Bells Inch 0 Elevator Pri-Recall <br /> 0 Speakers 0 Elevator Alt-Recall <br /> b) 0 Homs 0 Elevator Fire Light <br /> c) 0 Chimes 0 AHU Control Relays <br /> d) 0 Other 0 AUX Control Relays <br /> e) 0 Visual Signals Type: 15/75 30175 110 <br /> with audible with out audible <br /> f) 0 Local Annunciator <br /> 7. Signaling Line Circuits: <br /> Quantity&Style(See NFPA 72,Table 3-6)of signaling line circuits connected to system: <br /> Quantity: Style: Analog Network <br /> 8. System Power Supplies: <br /> a) Primary(Main): Nominal Voltage 120 VAC Current Rating 20 AMP <br /> Overcurrent Protection: Type Breaker Current Rating 20 AMP <br /> Location: <br /> b) Secondary(Standby): <br /> 24 vdc Storage Battery: Amp-Hour Rating 7 AH <br /> Calculated capacity to drive system,in hours. X 24 60 <br /> N/A Engine-driven generator dedicated to fire alarm system: <br /> Location of fuel storage: <br /> c) Emergency of Standby System used as backup to Primary Power Supply,instead of using a Secondary Power Supply: <br /> N/A Emergency System described in NFPA 70,Article 700 <br /> N/A Legally Required Standby System described in NFPA 70,Article 701 <br /> N/A Optional Stanby System described in NFPA 70,Article 702,which also meets the performance requirements of <br /> Article 700 or 701 <br /> 9.System Software <br /> a) Operating System Software Revision Level(s): Zeus 11.5 <br /> b)Application Software Revision Level(s): Zeus 11.5 <br /> c) Revision Completed by: Steve Dion Siemens Industry Inc-Tampa <br /> (name) (firm) <br /> 10. Comments: Final inspection of project <br /> Siemens Senior Technician <br /> (signed)for Central Station or Alarm Service Company or Installation Contractor (title) (date) <br /> Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standard(s): <br /> System deviations from the referenced NFPA standard(s)are: <br /> All devices are pre-existing system devices. They were relocated to new locations per Arch Specs. <br /> (signed)for Central Station or Alarm Service Company or Installation Contractor (title) (date) <br /> Upon completions of the system satisfactory test(s)witnessed(if required by the authority having jurisdiction): <br /> signe representative of G authority having jurisdiction (title) (date) <br /> name of facility <br /> Unrestricted 6/27/2018 job# <br />
The URL can be used to link to this page
Your browser does not support the video tag.