L A <br /> TFP620 <br /> Page 4 of 8 <br /> Where the area of Glazing is less than <br /> 14.2 linear meters, all window sprin- When acceptable to the Authority Having Jurisdiction the Model WS Specific Application <br /> klers on one side shall be calculated. Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect <br /> If an area reduction for quick response nonoperable window openings that are in an interior fire separation,the window sprinklers <br /> sprinklers is utilized,the linear length of are installed on both sides of the window in the fire separation. <br /> the calculated window sprinklers may <br /> be reduced,but in no case shall be less <br /> than 36 linear feet(1.2 x q900). <br /> If a single fire can be expected to INSIDE <br /> operate Model WS Window'Sprinklers <br /> and sprinklers within the design area of <br /> a hydraulically calculated system, the <br /> water demand of the window sprinklers INSIDE <br /> shall be added to the water demand of <br /> the hydraulic calculations and shall <br /> be balanced to the calculated area <br /> demand. FIGURE 3A-1-INTERIOR FIRE SEPARATION <br /> If the window sprinklers are located in <br /> an area other than the hydraulic design <br /> area,the demand of the window sprin- When acceptable to the Authority Having Jurisdiction the Model WS Specific Application <br /> klers is not required to be added to the Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect <br /> demand of the remote hydraulic design nonoperable window openings that are part of a fire separation provided in jurisdictions <br /> area.However,it is necessary to prove where exterior spatial separation is defined as protecting an adjacent building from.a fire <br /> hydraulically the simultaneous opera- in your building,window sprinklers are installed on the interior side of the glass. <br /> tion of the Model WS Window Sprin- <br /> klers and the ceiling sprinklers adjacent <br /> to the.window sprinklers. OUTSIDE <br /> Interior Protection Non-Sprinklered <br /> Building <br /> Calculate all sprinklers on the most <br /> demanding side of the glazing assem- INSIDE <br /> bly within the enclosure. <br /> EXPOSURE <br /> Exterior Exposure Protection SIDE <br /> Calculate all sprinklers controlled <br /> by the deluge valve using the design FIGURE 3A-2-EXTERIOR FIRE SEPARATION-SPRINKLERS INSIDE <br /> requirements of NFPA. <br /> Duration of Water Supply When acceptable to the Authority Having Jurisdiction the Model WS Specific Application <br /> Duration of water supply must comply Window Sprinklers may be used in either a sprinklered'or unsprinklered building to protect <br /> with requirements of NFPA. If window nonoperable window openings that are part of a fire separation provided in jurisdictions <br /> sprinklers are used to provide the where exterior spatial separation is defined as protecting your building from a fire in an <br /> equivalency of a fire rating, the water adjacent building,open window sprinklers are installed on the exterior side of the glass. <br /> supply must be capable of supplying <br /> water for the required rating period. <br /> Minimum Flow per Sprinkler INSIDE <br /> 20 GPM (75,7 LPM) for sprinkler <br /> spacing of 6 to 8 ft. (1,83 to 2,44 m) <br /> or 15 GPM (56,8 LPM) for sprinkler <br /> spacing less than 6 ft. (1,83 m). OUTSIDE <br /> Maximum Pressure per Sprinkler <br /> • Horizontal Sidewall:70 psi(4,83 bar)* EXPOSURE <br /> 'The 70 psi is only for cold solder SIDE <br /> purposes. If there is a baffle or a FIGURE 3A-3-EXTERIOR FIRE SEPARATION-SPRINKLERS OUTSIDE <br /> mullion of sufficient depth to act as <br /> a baffle,separating the sprinklers, FIGURE 3A (A-1 TO A-3) <br /> the maximum pressure is 175 psi TYPICAL NON-OPERABLE WINDOW OPENINGS <br /> (12,07 bar). _ . - <br /> • Vertical Sidewall: 175 psi(12,07 bar) <br />