My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19827
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19827
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2019 9:04:47 AM
Creation date
9/18/2019 9:04:46 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-19827
Building Department - Name
BARRETT,CHESTER & PATRICIA
Address
38623 4TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
07/16/2015 10:05 7278634273 ABC SUPPLY CO INC PAGE 02/04 <br /> FL 7271.11-R3 <br /> C1999-19 <br /> 3.20.15 <br /> Page 2 of 3 <br /> Manufacturer: Union Corrugating Company <br /> Product Nance: MasterRib Panel <br /> Panel Description: 36"wide coverage with 3/4"high ribs at 9"o.c. <br /> Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel(ASTM A653) <br /> or Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755). <br /> Support Description: Nom. 1" x 4" (min) lumber at max. 24" o.c. (Must be designed by <br /> others) <br /> Support Attachment: (1)49 x 3"long wood screw into rafters spaced at max 24"o.c. <br /> New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. <br /> Required for new construction and optional for reroofing construction. <br /> Existing Underlaytnent: One layer of asphalt shingles over one layer of 930 felt.For reroofing <br /> (Optional) construction only. <br /> Deck Description: Mir,7/16"thick OSB deck or min. 15/32"thick APA rated plywood or <br /> nun. -1/4' thick wood plank (Hain SG of 0.42) for new and existing <br /> constructions.Designed by others and installed as per FBC 2014. <br /> slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 <br /> Design Uplift Pressure: 71 psf for Fastener Pattern 1 <br /> (Factor of Safety=2) 114 psf for Fastener Pattern 2 <br /> Panel Attachment: #9-15 or #10-14 wood screw with washer. Fastener shall be of <br /> sufficient length to penetrate through the support and deck a minimum <br /> of 3/8". <br /> Pattern 1 a@ 9"o.c.across panel width <br /> Pattern 2 @ 5.5"-3.5"-5.5"o.c.across panel width <br /> Sidelap Attacbment: '/."-14 x 7/8" long SDS with washer@ 24" o.c. Recommended for <br /> (Optional) roof slope less than 3:12. <br /> Test Standards: Panel assembly tested in accordance with ASTM E1592-01 `Test <br /> Method for Structural Performance of Sheet Metal Roof and Siding <br /> Systems by Uniform Static Air Pressure Difference' and FM 4470 <br /> Section 5.5 `Resistance to Foot Traffic'. <br /> Code Compliance. The product described herein has demonstrated compliance with FBC <br /> 2014 Section 1507.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.