Laserfiche WebLink
"THE INCH"' <br /> 1b113 <br /> QUICK RESPONSE <br /> AUTOMATIC SPRINKLERS <br /> MODEL GL5606 <br /> FIRE SPRINKLER CORPORATION ONE INCH ADJUSTABLE <br /> DESCRIPTION AND OPERATION CONCEALED PENDENT <br /> The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, <br /> aesthetically pleasing design. It provides sprinkler operation approximately six times faster than <br /> ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are <br /> specified when allowed by the applicable standards. It offers the additional feature of greatly <br /> increased safety to life and should be used advisedly and under the direction of approving <br /> authorities having jurisdiction. The sprinkler is available with a nominal 1"of adjustment and a low <br /> profile cover plate assembly. All that is seen at the ceiling is a 3 5/16"diameter ceiling plate or an <br /> optional 2W diameter ceiling plate color finished to match the specifier's exact requirements. The <br /> GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the"smooth flow" <br /> of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located <br /> above the ceiling and concealed from view by the ceiling plate. <br /> The provided protective cap needs to be removed in order to install the sprinkler with the proper <br /> wrench.The protective cap must be replaced on the sprinkler until the time the cover plate is to be <br /> installed. The "push on -screw off' designed cover plate is easily installed and with a nominal 1" <br /> inch of adjustment makes it easier to get a proper fit at the ceiling. <br /> Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate <br /> to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes <br /> the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved <br /> pattern to extinguish or control the fire. <br /> TECHNICAL DATA <br /> •See reverse side for Approvals and Specifications. <br /> •Temperature Ratings- A-- <br /> t- ---� <br /> 135'F (57°C) Sprinkler, 1350F (57°C) Cover Plate; <br /> 1550F (68°C) Sprinkler, 1350F (57°C) Cover Plate; <br /> 155OF (68°C) Sprinkler, 155°F (68°C) Cover Plate; 3 5116"diameterplate <br /> 1750F (79°C) Sprinkler, 155OF (68°C) Cover Plate; <br /> 200°F (93°C)Sprinkler, 1550F (68°C) Cover Plate. <br /> •Water Working Pressure Rating - 175 psi (12 Bars). <br /> •Factory tested hydrostatically to 500 psi (34 Bars). MW <br /> •Maximum low temperature glass bulb rating is-670F (-550C). <br /> •Frame - bronze • Deflector- brass • Screw- brass <br /> •Bulb seat-brass • Spring - nickel alloy • Seal -teflon 2 314"diameter plate <br /> •Bulb -glass with alcohol based solution, 3mm size. QUICK RESPONSE <br /> •Drop Pin -stainless steel WHITE ADJUSTABLE <br /> •Cover Plate - brass CONCEALED PENDENT <br /> *Upper Escutcheon Assembly- plated steel. <br /> (VOTE. Globe's wrench P/N 332765 must be used to install this sprinkler. <br /> • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING <br /> CLASSIFICATION AVAILABLE BULB N.F.P.A. MAXIMUM CEILING <br /> SPRINKLER TEMPERATURES COLOR TEMPERATURE <br /> ORDINARY 13�6?�FQ% 56y°F 57,p68°C ORANGE/RED 1OQ'F= „`: 38 C <br /> .y y9M- -L .S"... • '.. i r ...7.. _ry,'P.:< _ �q 1, q._.:•.. <br /> INTERMEDIATE 175,°F7200'F 79°C/93°6 it YELLOW/GREEN 150°F <br /> 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989)846-4583 • FAX 989-846-9231 <br /> JULY 2009 A-38 BULLETIN GL5606 REV#5 <br />