My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20094
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20094
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:18:10 AM
Creation date
9/18/2019 9:53:33 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
18-20094
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
36763 EILAND BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Model <br /> 13 <br /> cousINSPECTOPIsTEST <br /> AF <br /> ® Model 3011 300„ ,, , Pressure <br /> APPR9VED Relief Valve Factory Rated at 175 PSI with other settings . - <br /> MODEL 3011A MODEL 3011ASG DIMENSIONS <br /> —B— Orifice Size Available:3/8",7/16", 1/2","/32", ELO(5/8") <br /> B~ i Model A B C D <br /> 1 o A 0 lil 3011A <br /> 1 31/16 411/16 77/8" 47/8" <br /> +I (75 mm) (118 mm) (200 mm) (124 mm) <br /> c 3011 ASG 31/16" 411/16" 95/16" 61/4" <br /> ® (75 mm) (118 mm) (237 mm) (159 mm) <br /> ° 3011 BV 31/16" 411/1 6" <br /> ID / V5 mm) (118 mm) <br /> 1 3011 SG 31/6" 411/16" 63/16" 31/8" <br /> © p5 mm) (118 mm) (157 mm) (79 mm) <br /> L -,L <br /> MODEL 3011 BV MODEL 3011 SG MATERIALS APPROVALS <br /> I— B—I Handle:Steel UL and ULC Listed: <br /> I. s <br /> I Stem: Rod Brass [EX4019(N)&EX4533(N)] <br /> Ball:C.P. Bronze FM Approved <br /> llil Body: Bronze NYC-BSA No.720-87-SM <br /> n O 1 c Valve Seat:Virgin Teflon°t Relief Valve: Bronze® �1 <br /> ° Bypass Fittings: Brass �1 <br /> 1 Bypass Tubing: Nylobraid <br /> Sight Glass: Bronze&Glass MADE IN U.S.A. <br /> FROM THE NFPA 13 2007 EDITION <br /> Models 3011 BV,3011 SG,3011A,&3011ASG,depending on the variant chosen,provide some or all of the requirements listed below: <br /> Chapter 8.16.2.4.1' Provisions shall be made to properly drain all parts of the system. <br /> Chapter 8.16.2.4.2 Drain connections, Interior sectional or floor control valve(s)-shall be provided with a drain connection <br /> &8.16.2.4.3 having a minimum size as shown in Table 8.16.2.4.2. <br /> Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. <br /> Chapter 8.16.2.4.6 The test connection shall be permitted to be used as main drain connection. <br /> Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... <br /> using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow <br /> equivalent to one sprinkler...(M3011SG and M3011ASG only) <br /> Chapter 8.17.4.2.2 The test connection valve shall be readily accessible <br /> Chapter 8.17.4.2.4 shall be permitted to be installed in any location ...downstream of the waterflow alarm. <br /> Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess <br /> of the maximum system pressure,whichever is greater. <br /> Chapter 8.16.1.2.3` A relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve <br /> set to operate at a pressure not exceeding 175 psi. <br /> Chapter A8.16.1.2.3 -consideration should be given to piping the discharge from the(pressure relief)valve <br /> Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion- <br /> resistant orifice,to provide a flow equivalent to one sprinkler... <br /> Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1", at least one of which shall be brass. <br /> USA Patent # 4971109 . !Other Patents Pending <br /> AGF Manufacturing Inc. Job Name: <br /> 100 Quaker Lane,Malvern,PA 19355 <br /> Phone:610-240-4900 Architect: <br /> ® Fax:610-240-4906 Engineer: <br /> www.testandrain.com <br /> Contractor: <br />
The URL can be used to link to this page
Your browser does not support the video tag.