My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20094
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20094
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:18:10 AM
Creation date
9/18/2019 9:53:33 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
18-20094
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
36763 EILAND BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MODEL PS40 (VdS) <br /> (2,) POTTER <br /> The Symbol of Protection `" SUPERVISORY PRESSURE SWITCH <br /> `UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA <br /> Accepted,CE Marked,VdS <br /> Dimensions:(9,6cm)3.78"W x(8,lcm)3.20"D x(10,7cm)4.22"H <br /> Conduit Entrance: Two knockouts provided for 1/2"conduit.Individual <br /> T i switch compartments and ground screw suitable for <br /> dissimilar voltages. <br /> P Enclosure: Cover-Die-cast with textured red powdercoat finish,single <br /> cover screw and rain lip. <br /> Base-Die-cast <br /> Pressure Connection:Nylon 1/2"NPT male <br /> Factory Adjustment: PS40-1 operates on decrease at 2,1 BAR(30 PSI) <br /> PS40-2 operates in increase at 3,5 BAR(50 PSI)and <br /> on decrease at 2,1 BAR(30 PSI) <br /> Pressure Range: 0,7-4,1 BAR(10-60 PSI) <br /> Differential: Typical 0,07 at 0,7 BAR(1 lb.at 10 PSI) <br /> 0,28 at 4,1 BAR(4 lbs.at 60 PSI) <br /> Maximum System Pressure: 17,2 BAR(250 PSI) <br /> Switch Contacts: SPDT(Form C) <br /> 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC <br /> One SPDT in PS40-1,Two SPDT in PS40-2 <br /> Models: PS40-1 VDS Environmental Specifications: <br /> PS40-2 VDS NEMA 4/IP66 Rated Enclosure-indoor or outdoor when used <br /> with NEMA 4 conduit fittings. <br /> Service Use = Temperature range:-40°C to 60°C(-40°F-140°F) <br /> Automatic Sprinkler NFPA-13 Tamper: Cover incorporates tamper resistant fastener that requires a <br /> One or two family dwelling NFPA-13D special key for removal. One key is supplied with each device. <br /> Residential Occupancy up to four stories NFPA-13R For optional cover tamper switch kit,order Stock No.0090200. <br /> National Fire Alarm Cade NFPA-72 See bulletin#5401200 PSCTSK. <br /> Installation Adjustment And Testing <br /> The PotterPS40 Series Supervisory PressureActuated Switches are designed The operation of the supervisory pressure switch should be tested upon <br /> primarily to detect an increase and/or decrease from normal system pressure completion of installation and periodically thereafter in accordance with <br /> in automatic fire sprinkler systems. Typical applications are: Dry pipe the applicable NFPA codes and standards and/or the authority having <br /> systems,pre-action air/nitrogen supervision,pressure tanks, air supplies, jurisdiction(manufacturer recommends quarterly or more frequently). <br /> and water supplies. The PS40 switch is factory set for 2,8 BAR(40 PSI) <br /> normal system pressure. The switch marked with the word LOW is set to Note. Testing the PS40 may activate other system connected devices. <br /> operate at a pressure decrease of,7 BAR(10 PSI)at 2,1 BAR(30 PSI). The The use of a Potter BVL(see product bulletin 8900067 for details)is <br /> switch marked with the word HIGH is set to operate at a pressure increase recommended to facilitate setting and testing of the PS40 pressure switch. <br /> of,7 BAR(10 PSI)at 3,5 BAR(50 PSI). See section heading Adjustments When a BVL(bleeder valve)is used,the pressure to the switch can be <br /> and Testing if other than factory set point is required. isolated and bled from the exhaust port on the BVL without effecting the <br /> 1. Connect the PS40 to the system side of any shutoff or check valve. supervisory pressure of the entire system. See Fig.3 <br /> 2. Apply Teflon tape to the threaded male connection on the device. <br /> (Do not use pipe dope) The operation point of the PS40 Pressure Switch can be adjusted to any <br /> 3. Device should be mounted in the upright position. point between 0,7-4,11 BAR(10 and 60 PSI)by turning the adjustment <br /> (Threaded connection down) knob(s)clockwise to raise the actuation point and counter clockwise to <br /> 4. Tighten the device using a wrench on the flats on the device. lower the actuation point. In the case of the PS40-2,both switches operate <br /> Wiring Instructions independent of each other. Each switch may be independently adjusted to <br /> 1. Remove the tamper resistant screw with the special key provided. actuate at any point acrosss the switch adjustment range. Initial adjustment <br /> 2. Carefully place a screwdriver on the edge of the knockout and sharply can be made with a visual reference from the top of the adjustment knob <br /> apply a force sufficient to dislodge the knockout plug. See Fig.9 across to the printed scale on the switch bracket. Final adjustments should <br /> 3. Run wires through an approved conduit connector and affix be verified with a pressure gauge. <br /> the connector to the device. A NEMA-4 rated conduit fitting is required <br /> for outdoor use. <br /> 4. Connect the wires to the appropriate terminal connections for the <br /> service intended.See Figures 2,4,5,6,and 8 <br /> PotterElectric Signal Company•St.Louis,MO•Customer Service:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com <br /> PRINTED IN USA WG.#5401161-REV D PAGE 1 OF 8 <br /> 09/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.