My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20102
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20102
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:18:45 AM
Creation date
9/18/2019 9:55:20 AM
Metadata
Fields
Template:
Building Department
Company Name
BEAR STEARNS COMERCIAL MORTGAGE
Building Department - Doc Type
Permit
Permit #
18-20102
Building Department - Name
BEAR STEARNS COMMERCIAL MORTGAGE
Address
7306 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br /> l <br /> General Installation Instructions Maintenance <br /> Model F3QR dry sprinklers must be installed only in stan- The Model F3QR Quick Response Dry Sprinklers should <br /> dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected and the sprinkler system maintained in accor- <br /> pipe tees in the horizontal position,even at branch line ends. dance with NFPA 25. Do not remove the factory applied <br /> They should not be installed into elbows or pipe couplings thermally sensitive wax fillet between the bulb supporting <br /> located on drop nipples to the sprinklers. For these and cup and the wrenching boss. Do not replace this wax with a <br /> other fittings including CPVC", the dry sprinkler should be substitute substance. An Alternate substance may interfere <br /> installed into a fitting to allow protrusion into the fitting in ac- with proper operation of the sprinkler.Do not clean sprinklers <br /> cordance with the diagrams. The "A" dimension of the dry with soap and water, ammonia or any other cleaning fluids. <br /> sprinkler,which extends into the freezers or a freezing zone Remove dust by using a soft brush or gently vacuuming. <br /> from wet pipe systems, should be selected to provide, as a Remove any sprinkler which has been painted (other than <br /> minimum,the specified lengths in inches shown in Fig. 10. factory applied) or damaged in any way. A stock of spare <br /> Caution: sprinklers should be maintained to allow quick replacement <br /> Do not install Model F3QR Dry sprinklers into CPVC of damaged or operated sprinklers. Prior to installation, <br /> adapter fittings or tees that have an internal obstruction. sprinklers should be maintained in the original cartons and <br /> This will damage the sprinkler and/or the fitting. Refer to packaging until used to minimize the potential for damage <br /> Fig. 11. to sprinklers that would cause improper operation or non- <br /> operation. <br /> During installation, the following steps must be followed: Caution: <br /> Use specified by RASCO wrenches only, which are <br /> 1. Cut the specified size hole(see illustrations)for the sprin- designed to engage sprinkler's wrenching pad. (Fig. 15, <br /> kler in the ceiling or wall directly in line with the tee. page 9) <br /> 2. Apply pipe joint compound to the 1" (25mm) pipe <br /> threads and install sprinkler using the Model F3 or <br /> XLO2 Sprinkler Wrench as specified. <br /> 3. Install the Model FP push-on /thread-off escutcheon <br /> or CCP cover plate if required. <br /> Note: Installation of the Model F3QR Sprinklers is not rec- <br /> ommended in copper pipe systems, as this may reduce <br /> the life expectancy of the sprinklers. <br /> Model F3QR Concealed and Recessed In- <br /> stallation Instructions <br /> • The Model XLO2 wrench (Fig. 12) is designed to lo- <br /> cate on the wrenching pads of the recessed sprin- <br /> kler while centering in the cup. A standard '/2" drive <br /> ratchet may be used to drive this wrench. Fig. 13 and <br /> Fig. 14 show sequentially the insertion of the wrench. <br /> First the wrench, with its jaws above the sprinkler de- <br /> flector, is moved laterally until centered with the cup. <br /> Then raise the wrench inside of the cup until its jaws <br /> engage the sprinkler's square wrenching pads (Fig. <br /> 14). To remove the wrench, follow this procedure in <br /> reverse order. Care should be taken to avoid striking <br /> the deflector, with the wrench. <br /> • Model F3 Wrench (Fig. 15) is used for installation of <br /> Pendent and Horizontal Sidewall sprinklers. <br /> • Glass bulb sprinklers have orange bulb protectors <br /> to minimize bulb damage during shipping, handling <br /> and installation. REMOVE THIS PROTECTION AT THE <br /> TIME THE SPRINKLER SYSTEM IS PLACED IN SER- <br /> VICE FOR FIRE PROTECTION. Removal of the pro- <br /> tectors before this time may leave the bulb vulnerable <br /> to damage. RASCO wrenches are designed to install <br /> sprinklers when covers are in place. REMOVE PRO- <br /> TECTORS BY UNDOING THE CLASP BY HAND. DO <br /> NOT USE TOOLS TO REMOVE THE PROTECTORS. <br /> 6. <br />
The URL can be used to link to this page
Your browser does not support the video tag.