<br /> P E A K/A'�nJM Peak Advantage Guarantee Charges and Requirements — Single Ply
<br /> VANTAGE Effective 5/30/2013
<br /> JM PVC Fully Adhered Membrane Systems
<br /> ( Term Price Membrane Seam Wind Hail,, Puncture
<br /> Type, Insulation(') Cover.Board!'�' - Flashings'" Notes
<br /> } (Yrs') (USM01 _ Thickness' Method Rider+'!- - Rider'?( Riders
<br /> ENRGY 3 br InV'mia-or to,56'ra 50 SD Hot Air `Sarne as i
<br /> New, RetroPlus or 60;60,FB;60 SD• Yes with 60 Mil `Yes with 60'Mil.
<br /> Approved Cover Board Weld Field -
<br /> $q "'.JM SECUROCK 80,80 FB„ 100. Membrane and Membrane and
<br /> 5/10,;'. ($350 Min.) "MPH Cover Board Cover Board
<br /> Invinsa or '50,50 FB;50 SD FB Membranes May Be.Adhered with'
<br /> ,� ENRGY3.or Hot Air Same as (2"Max) (16or32_Hrs:/Yr.)
<br /> Re-Cover' - RetroPlus or 60;60 FB-60 SD JM RSUA Direct to Approved Substrates.•
<br /> Approved Cover Board_ Weld Feld'
<br /> JM SECUROCK 80 80 FB Proper-Prep of all substrates.regdired
<br /> Invinsa or 50,50 FB,50 SD Hot Air Same as
<br /> New ENRGY 3(Required)(') RetroPlus or 60,60 FB,60 SD Weld Feld Yes with 60 Mil Yes with 60 Mil
<br /> ! $7 JM SECUROCK 80,80 FB 100 Membrane and Membrane and
<br /> 15 ($500 Min.) MPH Cover Board Cover Board
<br /> Invinsa or 50,50 FB,50 SD FB Membranes May Be Adhered with
<br /> i Re-Coverl" ENRGY 3 or RetroPlus or 60,60 FB,60 SD Hot Air Same as JM RSUA Direct to Approved Substratesj'. (2'Max.) (16 or 32 HrsJYr.)
<br /> Approved Cover Board JM SECUROCK 80,80 FB Weld Field Proper Prep of All Substrates Required
<br /> Invinsa on 60,60 FBI 60 SD Hot Air Same as'-
<br /> I New, ENRGY 3(Required)13j- Retrof'lusor
<br /> I 80,:80 FB' "Weld Feld Yes with ;Yes witl
<br /> i $10," JM"SECUROCK.. 100 -
<br /> 20 000 Mint
<br /> _ " ` • "I MPH" � Coyer�Board �,• :` -Cover.Board
<br /> Invinsa or'' {2'Max'.) :(16 ot32H�s./Yr.)
<br /> i Re-Covert'• RetroPlus.or.s . 6 '
<br /> ENRGY 3 or. 0;60 FB,60 SD Hot Air S'ame'as Moisture Scan or•Remove Roof cover•'
<br /> Approved Cover Board' .80,80 FB',,' ; - Weld- 'Feld and replace wet Insulation
<br /> JM SECUROCK ..
<br /> Invinsa or
<br /> JM SECUROCK Hot Air Same as 100
<br /> $12 New ENRGY3(Required) (Required Unless 80,80 FB,80 SD Weld Feld MPH Not Available
<br /> ' 25 ($1,000 Min.) ENRGY 3 25 PSI)
<br /> 1
<br /> i
<br /> Re-Cover Not Available
<br /> Invinsa or Hot Air. Satrle.as 90
<br /> New ENRGY 3(Required)•: -JM SECUROCK' 86,80 FB Not Available •,
<br /> 30.: $,15 (Required)... ' Weld _Feld MPH
<br /> 0,500 Min.)
<br /> Re-Cove}. Not Available
<br /> I
<br /> NOTES: MEMBRANE KEY:
<br /> All wind,hail and puncture riders are available for an additional charge. (2)All riders require prior written approval of the system requirements from 50,60,80,50 FB,60 FB,and 80 FB indicate JMPVC with DUPoriff Elvaloy®KEE
<br /> Reference individual wind,hail and puncture rider pages for system requirements JM Guarantee Services. 50 SD,60 SD,80 SD indicates JM PVC SD Plus
<br /> and charges.
<br /> (3)Pinnacle/Summit options available.Please contact local sales rep for details.
<br /> Non-JM metal may be included in the standard JM Peak Advantage Guarantee (4)Refer to the NRCA Roofing and Waterproofing Manual,Volume 3 Reroofing Part 1,
<br /> at no charge for.Pinnacle and Summit contractors or for a$2 00 per lineal foot Section 4.3.6—Existing System Preparation for guidelines on howto prepare and
<br /> upcharge for Peak contractors. re-cover over various existing roof systems.Please Contact Guarantee Services
<br /> (1)JM systems require either one layer of ENRGY 3 or an approved JM cover board for project-speck requirements.Insulation may be mechanically Fastened or
<br /> unless Fleece-Backed Membrane is adhered with JM RSUA.The use of Fleece- adhered with an approved urethane adhesive.Use of urethane adhesive requires
<br /> Backed with RSUA is limited to 10-year guarantees or 15-year guarantees for moisture scan and approval of Substrate by JM Guarantee Services
<br /> Summit and Pinnacle contractors.The use of JM SECUROCK in a single layer *SECUROCK is a trademark of USG Corporation
<br /> is limited to 15-year guarantees or 20-year guarantees for Summit and Pinnacle
<br /> contractors.See individual listings for speck requirements.
<br /> RS-2356-9 10-15(Replaces 8-13)