Laserfiche WebLink
OR BK 9999 PG 1884 Page 13 of 18 <br /> Grease waste interceptor location,design,and sizing shall be based upon the requirements found <br /> in the plumbing provisions of the Florida Building Code and implementing administrative rules. <br /> 57.20.2.2 Existing Service Facilities <br /> Existing service facilities that do not have a grease waste interceptor shall install a properly sized <br /> interceptor(s)in accordance with the plumbing provisions of the Florida Building Code. <br /> Plumbing connections shall be modified to accommodate the grease waste interceptor to comply <br /> with this sub-ordinance within 365 days from the effective date of this sub-Ordinance,unless <br /> , otherwise directed by the Administrator in writing. <br /> 57.20.2.3 UPGRADE OR REPLACE EXISTING GREASE WASTE INTERCEPTOR <br /> Existing service facilities that have a grease waste interceptor and are not in compliance with this <br /> sub-Ordinance shall be required to upgrade or replace the existing grease waste interceptor in <br /> accordance with the Florida Plumbing Code within 365 days of first notification. <br /> 57.20.2.4 NEW SERVICE FACILITIES <br /> All new grease waste interceptors installed at service facilities shall be of the type and capacity <br /> required by the plumbing provisions of the Florida Building Code and approved by the <br /> Administrator or his/her designee. <br /> 57.20.3 GREASE WASTE INTERCEPTOR MAINTENANCE <br /> A. Service facilities with interceptors having a greater than 20-gallon capacity are required <br /> to utilize a grease waste hauler permitted by Pasco County,Florida to pump grease waste <br /> from the grease waste interceptor.Any discharge,overflow or spill that leaves the <br /> confines of the grease interceptor and or sanitary sewer as a result of improper <br /> tt <br /> maintenance shall be classified as a"pass through"and shall result in a violation,subject <br /> f• to appropriate penalties,in accordance with sub-Ordinance 22,until such a time that the <br /> situation has been corrected and cleanup process is underway.Furthermore,the business <br /> owner or designee must notify the Florida Department of Business and Professional <br /> Regulations,Division of Hotels and Restaurants,within 24 hours of incident at its current <br /> listed telephone number. <br /> B. The service facility shall report pumping activities within five business days to the <br /> Administrator on the form so designated by the City of Zephyrhills for such purposes. <br /> C. In-ground grease waste interceptors shall be monitored at a minimum frequency of once <br /> for every 90(ninety)days to determine if the standard is met.The schedule for pumping <br /> shall be established by the Administrator.A registered service facility may file a request <br /> for an alternate pumping frequency with the Administrator.Based on the results of the <br /> monitoring report and the deviation from the standard,if any,the Administrator may <br /> adjust the pumping frequency,but pumping frequency shall not exceed 180 days.If the <br /> standard is not met,an increased pumping frequency shall be required. <br /> D. The Administrator may require that,at the service facility's expense,appropriate <br /> t_ monitoring facilities,such as a control manhole,be installed. <br /> tom_ <br /> E. Grease waste interceptor cleaning and maintenance shall include pumping the grease <br /> waste interceptor until empty,and cleaning the side walls,baffle walls,cross-pipes and <br /> inlet and outlet pipes.Internal piping shall be immediately restored to their original <br /> design configuration should any damage occur.If multiple grease waste interceptors are <br /> installed,all traps in the series must be pumped and cleaned according to the maintenance <br /> schedule. <br /> F. No emulsifiers,grease cutters or other chemicals,which could cause grease to pass <br /> through the grease waste interceptor may be used in the maintenance of a grease waste <br /> -13- <br />