Laserfiche WebLink
SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E. <br /> PLOT PLAN NOT A BOUNDARY SURVEY <br /> BEARING BASIS: <br /> LOT 2-5, BLOCK 5 <br /> SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E <br /> PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT <br /> 1�y. MAY BE DISCLOSED BY A FULL AND ACCURATE <br /> TITLE SEARCH, ALSO SUBJECT TO SETBACKS, <br /> EASEMENTS AND RESTRICTIONS OF RECORD. <br /> ,0 UNDERGROUND FOOTER, STEM WALL, AND <br /> I UNDERGROUND UTILITIES ARE NOT LOCATED OR <br /> \ SHOWN. <br /> \ \ EA DO NOT SCALE THIS PRINT. DIMENSIONS AND <br /> NOTES TAKE PREFERENCE. <br /> \ TRACT E <br /> COMMON AREA DESCRIPTION NOT CONTAINING PLAT BOOK AND <br /> _o PAGE INDICATES THAT PLAT IS IN <br /> FLOOD PRELIMINARY STAGE AND IS SUBJECT TO <br /> ZONE CHANGE AND/OR REVISION. <br /> A, CERTAIN DATA SHOWN HEREON BASED ON <br /> TRACT E / ENGINEERING PLANS PROVIDED BY CLIENT. <br /> CONSELAND <br /> RVATION WETLAND tij o / STRUCTURE TIES SHOWN HEREON DENOTES <br /> AREA / LINE FLOOD <br /> o ZONE MEASUREMENT FROM FORM BOARDS/FOUNDATION <br /> / TO PROPERTY LINE. <br /> 10' UTILITY EASEMENT <br /> ��ti so:•• / PRELIMINARY DRAWING: <br /> / THIS PLAN IS FOR PERMITTING PURPOSES <br /> a� ONLY, NOT FOR CONSTRUCTION. VERIFY <br /> 0. BLOCK 5 ALL DIMENSIONS BEFORE ANY CONSTRUCTION. <br /> 5.59'(C) / 0 LEGEND: <br /> 6.59'(P) / 9�, ��: —vv.— = PROPOSED DRAINAGE FLOW <br /> (00.00) = PROPOSED GRADE <br /> E-00.00 = EXISTING GRADE <br /> NOTES: <br /> i° / 5 p50/ S g e2 Je• j LOT GRADING TYPE = B <br /> Q o <br /> v�i I �ti0���1 PROPOSED PAD ELEVATION = 103.5' <br /> 9 OQO� �� FRONT SETBACK = 20' <br /> FLOOD (10350) <br /> O 5 SIDE SETBACK = 7.5' <br /> t.0 ZONE 1`' Q p6 Ry l g <br /> y A" / 'ST oe v0l,& �so,REAR SETBACK = 15' <br /> O 9 s, <br /> FLOOD <br /> a ZONE 2 v <br /> 2 X 20• S <br /> Z APPROXIMATE LOCATION :;bgy- :''? / o•- <br /> OF FLOOD LINE S 4. :•;?G 2 <br /> 76. p, <br /> If- 1h. <br /> U¢ ON LOT AREA CALCULATIONS <br /> m LOT = 9191.97_SQ. FT. z,� ":�'%: '. •n0 00„= <br /> r.. <br /> i LIVING AREA = 1880_SO. FT. LOT 26 <br /> ENTRY = 159----SQ. FT. BLOCK 5 <br /> GARAGE = 679 SQ. FT. / a <br /> Q /•..:•N .•M <br /> COVERED LANAI = N/A Q. FT. <br /> dam.• PATIO = N/A—_SQ. FT. ` <br /> un CONC. DRIVE = 1081—SQ. FT. I "co) <br /> A/C & CONC PAD =_?5----SQ. FT. M: <br /> PRIVATE SIDEWALK = 27 _SQ. FT. J/ <br /> IMPERVIOUS = 42 7 PCPIURAD <br /> S) <br /> = 3851 _SQ. FT. POINT <br /> SOD = 5341 --SQ. FT. <br /> 3 OFF LOT AREA CALCULATIONS (10226 ;`C 29 <br /> v, RIGHT OF WAY = 88210 _SQ. FT. ti <br /> N DRIVE APRON = 239 __SQ. FT. <br /> 1i PUBLIC SIDEWALK = 358 SQ. FT. -'r �PGP� <br /> SOD =_ 285 -SQ. FT. <br /> Rd �pl <br /> m TOTALS nA vV <br /> AREA = 10074.07 SQ. FT. <br /> DRIVEWAY = 1320 _SQ. FT. P(�pGZ G) <br /> °Q SIDEWALK = 65 SQ. FT. <br /> 5 ��oo vpR1E5) <br /> � SOD = 626 Q. FT. <br /> 2 <br /> a <br /> DESCRIPTION: PROPOSED: <br /> z LOT 25, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO LOWEST FLOOR ELEVATIONS: <br /> O RANCH SUBDIVISION PHASES 6, 8 & 9A", AS RECORDED LIVING AREA: 104.20' <br /> 9 IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE GARAGE AREA: <br /> uj PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO <br /> CURVE RADIUS ARC CHORD BEARING DELTA <br /> NORTH AMERICAN VERTICAL <br /> QC129 1 25.00' 1 7.26' 1 7.23' 1 S 0133'39" E 1 16.37.40" DATUM OF 1988. MEAN SEA <br /> ON C130 55.00' 66.58' 1 62.59' 1 S 24-48.22" w 1 69-21.42" LEVEL= 00.00 FT. <br /> a <br /> APPARENT FLOOD HAZARD ZONE: "X&A" COMMUNITY PANEL N0. 120230 0455 D EFFECTIVE DATE: 09/30/1992 <br /> 00 <br /> 'd Project Number: Square Feet: 9191.97t LENNAR HOMES <br /> v LEGEND: <br /> m(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %7- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= <br /> CL CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, <br /> =F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED <br /> U PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT <br /> Z REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, <br /> 9 U P= UTILITY POLE, W F= WOOD FENCE <br /> Cp JOHN R.BEACH&ASSOCIATES,INC. Drawn By. <br /> SMS <br /> SURVEYORS AND MAPPERS Checked By. <br /> 911 WEST ST. PETERSBURG DRIVE JRB <br /> ONE OLDSMAR, FLORIDA 34677 <br /> N WAY (813) 854-1276 FAX (813) 855-8370 Scale: <br /> 1'=30' <br /> O NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 1/28/19 ACS <br /> THE ORIGINAL RAISED SEAL OF A FLORIDA S A DATE <br /> LICENSED SURVEYOR AND MAPPER Id JOHN R. B H <br /> Revisions: FLORIDA REG. ND SURVEYOR No. 2984 LB 4493 <br /> v1 JEFF M. HAR <br /> i URVEYOR & MAPPER No.7123 <br /> LL <br />