My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21019
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 9:51:10 AM
Creation date
1/7/2020 9:51:08 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21019
Building Department - Name
MEIER,BRANDON
Address
38607 4TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�`. INSTALLATION NOTES: Alpum <br /> 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION ATRIUM CORPORATION ;`,ti' <br /> r SHOWN. R'IX Do Ts AXD D 0 a A <br /> 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM SERIES 120/130 ATRIUM WINDOWS AND DOORS <br /> NUMBER OF ANCHORSTO BE USED FOR PRODUCT INSTALLATION OF THE �sssow <br /> MAXIMUM SIZE LISTED. e.uns.3Duls(M' <br /> 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF t1/2 <br /> HORIZONTAL SLIDER vx:Nu s3�-IG96 IAL tZ1<WZad736 <br /> INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL(I.E., Z: <br /> WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES ARE NOT r/i m m X <br /> CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. p r Z O Q i a <br /> 0 m 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING .My H ¢ p S--d a a 3 9 <br /> ^ <br /> SHIM(5).MAXIMUM ALLOWABLE SHIM STACK TO BE 1/41NCH.SHIM WHERE O w (0 m m a a- <br /> SPACE OF 1/161NCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED n e7 Z 2.1 d�I <br /> OF HIGH DENSITY PLASTIC OR BETTER. - <br /> GENERALNOTES: <br /> Ccr O m� <br /> S. THROUGH FRAME:FOR INSTALLATION INTO WOOD FRAMING USE#10 W a <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED F y <br /> to m <br /> WOOD-SCREWS THE FRAME OF SUFFICIENT LENGTH TO ACHIEVE 1 O g <br /> 1/2 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. TO COMPLYE CURRENT I AND CURRENT FLORIDA <br /> BUILDING CODE(FBC),EXCLUDING HVHZ x a W a <br /> AND HAS BEEN <br /> 6. THROUGH FRAME:FOR INSTALLATION THROUGH 1X BUCK TO EVALUATED ACCORDING TO THE FOLLOWING: TABLE OF CONTENTS J z a <br /> CONCRETE/MASONRY,OR DIRECTLY INTO CONCRETE/MASONRY,USE 3/16 • AAMA/WDMA 101/I.S.2/A440-05/08 r i <br /> INCH DIAMETER ITW TAPCONS OF SUFFICIENT LENGTH TO ACHIEVE 11% SHEET REVISION SHEET DESCRIPTION <br /> 4 _ <br /> INCH MINIMUM EMBEDMENT. 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY REMARKS BY DATE <br /> AND 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM 1 C GENERAL&INSTALLATION NOTES <br /> CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED A-FBC Sth ED.CODE CHANGE SM 06.03.14 <br /> 7: THROUGH FRAME:FOR INSTALLATION INTO METAL STUD OR APPROVED 2 C ELEVATIONS <br /> MULLION USE#10 GR..5 SELF TAPPING SCREWS THROUGH THE FRAME OF PRODUCT LOADS TO THE FOUNDATION ISTHE RESPONSIBILITY OF 9-74"X63"DP REVISION tAGi7 <br /> SUFFICIENT LENGTH TO ACHIEVE A MINIMUM OF 3 THREADS PENETRATION THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF 3 C ANCHOR LAYOUTS C-FBC 2017 CODECHANGE <br /> BEYOND METAL FRAME SUBSTRATE. INSTALLATION. <br /> 4 C VERTICAL SECTIONS&GLAZING DETAIL <br /> 8. THROUGH FIN:FOR INSTALLATION INTO WOOD FRAMING USE#8 WOOD 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND 5 C HORIZONTALSECNONS IMe�xovwi xor.eieaouuaow aie <br /> SCREWS THROUGH THE FIN OF SUFFICIENT LENGTH TO ACHIEVE 11/21NCH ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE WiMOUfNAnTaVC9xSEM Oi MtpxG D0.0�WG <br /> STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE .�Pp,GT10N5•"p0A10Nx"w""Gx""c*00.°s"t^ <br /> MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR s*oµs oomavrtxorenr�ncoaxo <br /> 9. THROUGH FIN:FOR INSTALLATION INTO METAL STUD OR APPROVED THE PROJECT OF INSTALLATION. Digitally signed6yjQX.➢Nomm.P.E <br /> -. MULLION USE#8 GR.5 SELF TAPPING SCREWS THROUGH THE FIN OF Reason:I a��qq��aPAt66 <br /> 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND Date:20 9Yj: ,D5 <br /> nt <br /> SUFFICIENT LENGTH TO ACHIEVE AMINIMUM OF3THREADS PENETRATION \iG" V <br /> MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE.IF <br /> BEYOND METAL FRAME SUBSTRATE. �Q� <br /> SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE MAX OA SIZE <br /> 5 REQUIREMENTS DETAILED HEREIN,A LICENSED ENGINEER OR `Z O <br /> 30. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, DESIGN MISSILE IMPACT •� <br /> ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE CONFIGURATION PRESSURE RATING 7 <br /> INCLUDING BUT NOT LIMITED TO STUCCO,FOAM,BRICK VENEER,AND SIDING. WIDTH HEIGHT r <br /> WITH THIS DOCUMENT IN NON-HVHZ AREAS. <br /> 11. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF :• T T qF <br /> CORROSION RESISTANT MATERIAL OR HAVEACORROSION RESISTANT 5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS 74" SO" XO +/-50 PSF NON-IMPACT / <br /> COATING. PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 74" 63" XO +/-35 PSF NON-IMPACT i Ox, <br /> $ 6. WINDOW FRAME MATERIAL:PVC 108" SO" XOX +/-50 PSF NOWIMPACT '����SS/••••••••�C�G\���` <br /> 5 12. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL <br /> INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS 7, DISSIMILAR METALS INCLUDING FASTENERS THAT MAY COME INTO 108" 63" XOX +/-30 PSF NON-IMPACT <br /> MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO CONTACT WITH ALUMINUM UNIT FRAMING SHALL BE PROTECTED a.OWA PX_xa 7377a <br /> FACE SHELL OF BLOCK. a <br /> IN ACCORDANCE WITH THE CURRENT FBC ueoix c oRa <br /> see a uM MOPs,we <br /> e1w. ale <br /> 5 13. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR EBPE CERT.of wmoavwna xo 2ss7a <br /> .E MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT 8. GLASS SHALL MEET THE REQUIREMENTS OF ASTM E 1300 GLASS <br /> F <br /> BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM CHARTS.SEE SHEET 4 FOR GLAZING DETAIL. FL#: <br /> STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. F L20472 <br /> 9- ALL SILL PENETRATIONS(WHETHER OR NOT FILLED WITH AN <br /> 14. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON INSTALLATION ANCHOR)ARE TO BE OVER SEALED WITH AN <br /> DATE: 10.03.17 <br /> SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: <br /> APPROPRIATE SILICONE SEALANT. <br /> c A.WOOD-MINIMUM SPECIFIC GRAVITY OF0.55. DWG.B CHK.BY: <br /> B.CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF3000PSI. AR/AG HFN <br /> C.GROUT-FILLED CMU-UNIT STRENGTH CONFORMS TO ASTM C-90 WITH SCALE: NTS <br /> s MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AND GROUT CONFORMS •I <br /> E TO ASTM C476,MINIMUM GROUT COMPRESSIVE STRENGTH OF 200D PSI. DWG.#: ATR116 <br /> D.HOLLOW BLOCK CMU-UNIT STRENGTH CONFORMS TO ASTM C-90 WITH <br /> MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI. SECTION: <br /> E.STEEL-MINIMUM YIELD STRENGTH OF 33 KSI.MINIMUM 18 GA.WALL <br /> THICKNESS. <br /> F. ALUMINUM-MINIMUM ALLOY 6063-TS.MINIMUM WALL THICKNESS OF <br /> 1/16"(0.0625"). OF 5 <br />