Laserfiche WebLink
S <br /> 23.Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hotwater'pipe insulation <br /> insulation for hot water pipe with a minimum thermal resistance(R-value) of R-3 shall.be applied to the <br /> following: <br /> Piping 3h inch (19.1 mm) and larger in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located.outside the conditioned space._ <br /> Piping from the water heater to a distribution manifold:_ <br /> Piping located under a floor-slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy ofthe energy cacls shall be with permit at all tunes. <br /> 27. CopV of final insulation report shall be provided ivith peen:it before rnal <br /> 28. No fence, pool or screen enclosure .is issued with:thisperinit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-:Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.b.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />