Laserfiche WebLink
D <br /> Q <br /> o <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.shall be a ininimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded t . .comply with R401.3 of the F.B.C. <br /> 3: Compaction test required.if 24"or more of fill dirt is brought in at any one-place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O:W.use permit. klr4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 1.. All property markers shall be uncovered and.m ifked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9; No electric,.plumbing,-mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply With section R302.6 of the EB' .C..(Fire Separation). <br /> l i. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303 A of the F-.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the RB.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. MI-308.:1, <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1-5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> . <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance-with the-F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />