Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2277E sf ADS Carrier VW Builder Name: Lennar Homes 0527 <br /> Street: 35885 Saddle Palm Way Permit office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1672.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1314.70 ft2 <br /> b.Frame-Wood,Exterior R=11.0 234.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 122.67 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2278.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2278.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2278 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(197.8 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 455.6 <br /> a. U-Factor: Dbl,U=0.33 125.85 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: -SHGC=0.34 a.Central Unit 35.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.33 32.00 ft2 <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.065 ft. <br /> Area Weighted Average SHGC: 0.249 14.Hot water systems <br /> 8. Floor Types (2278.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2278.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.087 Total Proposed Modified Loads: 63.67 PASS <br /> Total Baseline Loads: 67.23 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Tk1E S7,g"y <br /> �� r <br /> this calculation are in compliance with the Florida Energy _specifications covered by this <br /> Code. calculation indicates compliance �'��,,,r '_',;,�;a� V <br /> 'Dave with the Florida Energy Code. /frrr, ;�' ;•� a O <br /> PREPARED BY: Before construction is completed ' <br /> DATE: this buildingwill be inspected for <br /> 1'f <br /> compliance with Section 553.908 * - <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. Cop yam;7AV ._ <br /> OWNER/AGENT: MAR 12 2019 BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. <br /> 3/7/2019 2:41 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br />