My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21125
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21125
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 11:09:01 AM
Creation date
1/7/2020 11:08:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21125
Building Department - Name
LENNAR HOMES LLC
Address
35893 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t 1 <br /> FORM R405-20'17 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall lype <br /> _ 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 157.3 ft2 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 8 437.3 ft2 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 40 8 320.0 ft2 0 0.600000 0 <br /> 5 N=>NE Exterior Frame-Wood Main 11 29 4 8 234.7 ft2 0.23 0.01 0 <br /> 6 W=>NW Garage Frame-Wood Main 11 15 4 8 122.7 ft2 0.23 0.01 0. <br /> 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2. 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 32.0 ft2 6 ft 4 in 0 ft 4 in None None <br /> 2 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 3 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 4 S=>SW 7 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 2 ft 0 in 0 ft 6 in None None <br /> 5 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 69.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 6 W=>NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 8.8 ft2 1 ft 0 in 0 ft 10 in None None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 617ft2 617ft2 49ft 8ft 1 <br /> INFILTRATION <br /> # Scope_ Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 2126.1 116.72 .219.51 .2649 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 <br /> 3/7/2019 2:41 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.