My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21138
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21138
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 9:24:38 AM
Creation date
1/7/2020 11:16:29 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21138
Building Department - Name
GARDNER,JIMMY
Address
5847 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e9eee��ee� <br /> • <br /> O • <br /> ♦ e <br /> Seats <br /> �®000ee <br /> easyseals.com <br /> DESIGN CALCULATIONS <br /> FOR <br /> GREASE MONKEY <br /> FREESTANDING SIGNS <br /> 5847 Gall Blvd—Zephyrhills <br /> GENERAL NOTES: <br /> 1. Design is in accordance with the Florida Building Code 6th Edition(2017) <br /> for use within and outside the High Velocity Hurricane Zone(HVHZ). <br /> 2. Wind loads have been calculated per the requirements of ASCE 7-10 as <br /> shown herein,except where noted otherwise. <br /> 3. These engineering calculations pertain only to the structural integrity of <br /> those systems, components,and/or other construction explicitly Index: <br /> specified herein and/or in accompanying engineering drawings. The Pg 1 Cover <br /> existing host structure(if any)is assumed to be in good condition, Pg 2 Wind Loads <br /> capable of supporting the loaded system,subject to building department pg 3 Footing Design <br /> approval.No warranty,either expressed or implied,is contained herein. Pg 4 Primary Supports) <br /> 4. System components shall be as noted herein. All references to named <br /> components and installation shall conform to manufacturer's or industry <br /> specifications as summarized herein.. <br /> S. Where site conditions deviate from those noted herein revisions may be "011IR11111", <br /> Y E`gi � � ir�Sh seal valid <br /> required or a separate site-specific engineering evaluation performed. ,. <br /> 6. Aluminum components in contact with steel or embedded in concrete <br /> shall be protected as prescribed in the 2015 Aluminum Design Manual, No.673 <br /> Part 1-A. Steel components in contact with,but not encased in,concrete a <br /> shall be coated,painted,or otherwise protected against corrosion. <br /> 7. Engineer seal affixed hereto validates structural design as shown only. ®'�®�.° F <br /> �f 01 <br /> Use of this specification by contractor,et.Al,indemnifies and saves <br /> Chrlsfi,a P #67382 <br /> harmless this engineer for all costs&damages including legal fees& �i, .® <br /> apellate fees resulting from deviation from this design. Easy SeAlsiot® agla'rY Auth#31124 <br /> 1200 N Federal Hwy,#200 <br /> Boca Raton,FL 33432 Easy Seals.com Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.