Laserfiche WebLink
FORM R405-'2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent S ace Cavity Width Height Sheathing Framing Solar Below <br /> r Tn M/ IThe P R-Value Fr do Ft In Arpa R-Valie_Emctton Ahcnr Gra ° <br /> _1 N Exterior Concrete Block-Ext Insul Main 5 56 8 8 0 453.3 ft' 0 0 0.2 0 <br /> -2 E Exterior Concrete Block-Ext Insul Main 5 38 0 8 0 304.0 ft' 0 0 0.2 0 <br /> -3 S Exterior Concrete Block-Ext Insul Main 5 47 4 8 0 378.7 fF 0 0 0.2 0 <br /> -4 W 'Eiferibr Concrete Block-Ezt Instil Maih 5 16 8 8 0 133.3'ft' 0 0 '0.2 0 <br /> -5 S Garage Frame-Wood Main 13 9 4 8 0 74.7 ft' 0 0.25 0.01 0 <br /> 6 W Garage Frame-Wood Main 13 21 4 8 0 . 170.7 ft' 0 0.25 0.01 0 <br /> DOORS <br /> # Omt DocrType Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 W Insulated Main None .46 2 8 6 8 17.8 ft' <br /> WINDOWS <br /> Orientation shown is the entered,Proposed orientation. <br /> Wall Overhang <br /> # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation inl Shade Screening <br /> 1 N 1 TIM Low-E Double Yes 0.65 0.35 N 4.3 ft' 10 ft 0 in 0 ft 2 in Drapestblinds Exterior 5 <br /> 2 N 1 TIM Low-E Double Yes 0.65 0.35 N 12.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 3 N 1 TIM Low-E Double Yes 0.65 0.35 N 30.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 4 N 1 TIM Low-E Double Yes 0.65 0.35 N 30.0 ft' 1 ft 0 in 1 ft 0 in Drapesiblinds Exterior 5 <br /> 5 E 2 TIM Low-E Double Yes 0.65 0.35 N 33.3 ft' 10 ft 0 in 0 ft 8 in None None <br /> 6 E 2 TIM Low-E Double Yes 0.65 , 0.35 N 15.0 ft' 1 ft 0 in 2 ft 7 in Drapes/blinds Exterior 5 <br /> 7 E 2 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft' 1 ft 0 in 6 ft 6 in Drapes/blinds Exterior 5 <br /> 8 S 3 TIM Low-E Double Yes 0.65 0.35 N 30.0 ft' 1 ft 0 in 1 ft 0 in Drapes blinds Exterior 5 <br /> 9 W 4 TIM Low-E Double Yes 0.65 0.35 N 20.0 ft' 6 ft 0 in 0 ft 8 in None None <br /> 10 W 4 TIM Low-E Double Yes 0.65 0.35 N 30.0 ft' 6 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 483.51 ft' 483.51 ft' 64 ft aft 1 <br /> INFILTRATION <br /> # Scope Method SEA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 1594.1 87.52 164.59 .1303 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ Split HSPF:8.2 32.6 kBtu/hr 1 sys#1 <br /> 3/6/2019 4:27 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)'Compliant Software Page 3 of 4 <br />