19-21148
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21148
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 11:20:49 AM
Creation date
1/7/2020 11:20:48 AM
Metadata
Fields
Template:
Building Department
Company Name
BUTTERFIELD INVESTMENTS INC
Building Department - Doc Type
Permit
Permit #
19-21148
Building Department - Name
BUTTERFIELD INVESTMENTS INC
Address
5016 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: R0219093 <br /> wrightsoft- Date: 03-06-19 <br /> Entike House By: AMA <br /> Bahrs Propane Gas&AC Inc <br /> 4441-Pdlen,Rd,Zephyrhills,FL33541 Phone:613-782-5013 <br /> Project Information <br /> For: <br /> SGIO 18th St,Zephyrhills,FL 33542 <br /> Cooling'Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4'F Sensible gain: 25291 Btuh Entering coil DB: 81.1'F <br /> Outdoor design WB:. 77.2°F Latentgaim, 4395 Btuh Entering coil WB: 65.0°F <br /> Indoor design DB: 75.0°F Total gain: 29686 Btuh <br /> Indoor R-H: 50% Estimated airflow-, 1133 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: 3 Ton-Franklin or Model: GSZ14036+ASPT37 <br /> Actual airflow: 1133 cfm <br /> Sensible capacity: 25500 Btuh 101%of load <br /> Latent capacity: 8500 Btuh 193%of load <br /> Total capacity: 34000 Btuh 11 Ho of load SH R: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 20559 Btuh Entering coil DB: 69.1'F <br /> Indoor design DB: 70.0'F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer: 3 Ton-Franklin or Model: GSZ14036+ASPT37 <br /> Actual airflow: 1133 cfm <br /> Output capacity: 32600 Btuh 159%of load Capacity balance. 32 *F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 'F <br /> Backup equipment type: EJec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1133 cfm <br /> Output capacity: 10.0 kW 166%of load Temp.rise: 27 *F <br /> Meets all requirements ofACCA Manual S. <br /> wrightsoft. 2019-Ma't-06 13:43:60 <br /> Right-SWMD Universal 2018 18.0.32 RSU20M Page 1 <br /> AC�Ck...momnam7.;;;0-181h-L-MM9093.rup Cale-MJS FrordDootfaces: W <br />