Envelope Leakage Test Report (Blower Door Test)
<br /> Residential Prescriptive, Performance or ERI Method Compliance
<br /> 2017 Florida Building Code, Energy Conservation, 6th Edition
<br /> Jurisdiction: City of Zephyrhills Permit#: 21148
<br /> Job Information:
<br /> Builder: Jeff bh(o -..
<br /> -�oeh ri n Communitjr',..�"" _.'- .-.- -- Lot:
<br /> Address: 501618th Street Unit:..
<br /> City: Zephyrhills State: ` FLORIDA Zip: 33542,
<br /> Air Leakage Test'Results: Passing results must meet&her the Perforrriance,Prescriptive;or ERI Method.,-..
<br /> ® PRESCRIPTIVOMETHb'D-The 6uild'ingoirdwe'llihg unit-shall betested,.and verified as having an air lea.kage rate I of not exceeding 7 air changes
<br /> per hour at a pressure of.0.2 inch w.g:,(50Y,0ascals)in'.Clirriate Zones 1 and 2.
<br /> ❑ PERF,ORM.A.NCE or ERI METHOD-The.building or dwelling unit shall be tested and verified as having an;airleakage rate of not exceeding the
<br /> selected ACH(50)value,asshown on FORM R405-20J 7(Performance)or R406-2017(ERI),section labeled as Infiltration,sub.=section ACH
<br /> �OACH(50)specified on Form R405 2017-Ever Calc(Performonce)or R406-2017(ERI):
<br /> Method for calculating building volume
<br /> 1284 X 60 13664 = 5.64 - ® Retrieved from architectural plans
<br /> CF00i ,Building Volume ACH(s0);
<br /> ❑ Code software calculated
<br /> ® PASS 0'�- _FALL
<br /> ID When ACH(50)is,less than 3 ACHso,-Mechanical Ventilation Field measured and;calculated Field measured;and calculated
<br /> installation,must be verified,by building department.
<br /> Testing.Testings6ll be conducted in accordance with ANSI/RESNET/IC680and reported at pressure or0.2 inches w:g:(50 Pascals).Testing shall he conducted byeither
<br /> individuals asdefined in Section 553.993(5)or(7),F/oridaStatues,orindividuals licensed as setforth in Section
<br /> 489.105(3)(Q,(g),or(i)or an approved third party.Awritt6n report ofthe results ofth6testshall besigned bythe party c9nducting the test and provided tothecodeofficial.
<br /> Tesfingshallbeperformedatanytimeaftercreationofailpenetrationsoftheboildingthermplenvelope;,` -
<br /> During testing:
<br /> L Uterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weather-stripping or other infiltration control measures.
<br /> 2 Dampers including exhaust,intake,makeup air,back draftand flue dampers shall be closed,but notsealed beyond intended infiltration control measures.
<br /> 3.Interior doors,if installed atthe time of the test,shall be open.
<br /> 4:.,Extehor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
<br /> S.'Heating and cooling systems,ifinstalled atthe time of the test,shall be turned off.
<br /> 6.Supply'and return registers,if installed at the time of the test,shall be full open. '
<br /> Testing Company
<br /> Compariy,iVame: airEnalasys'` Phone: 877-431,-**7728
<br /> I hereby verify that the.above Air Leakage results are.in accordance with the 2017 6th,Edition-Florida Building Code Energy,
<br /> Conservation requirements according to the compliance method-selected above: `
<br /> Signature ofTester: ;: li(�,.'' Q�l,O,. Date of Test: T1%12/19
<br /> Printed Name of Tester:`` William Mago' .
<br /> License/Certification# 4305320.,., ` Issuing Authority: ` .y FSEC RESNET