My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21149
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21149
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 11:22:57 AM
Creation date
1/7/2020 11:22:56 AM
Metadata
Fields
Template:
Building Department
Company Name
BUTTERFIELD INVESTMENTS INC
Building Department - Doc Type
Permit
Permit #
19-21149
Building Department - Name
BUTTERFIELD INVESTMENTS INC
Address
5010 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> / Adjacent Cavity Width Height Sheathing Framing Solar Below <br /> V#Omt To Wan Tyne Space a-Value Fe inFr_t. Am. R_value-Faction-Absn <br /> _1 N Exterior Concrete Block-Ext Insul Main 5 66 0 8 0 528.0 ft' 0 0 0.3 0 <br /> -2 E Exterior Concrete Block-Ext Insul Main 5 42 8 8 0 341.3 ft' 0 0 0.3 0 <br /> -3 S Exterior Concrete Block-Ext Insul Main 5 45 8 8 0 365.3 ft' 0 0 0.3 0 <br /> -4 W Exterior- Concrete Block-Ext Insul Main 5 21 0 8 0 168.0 ft' 0 0 0.3 0 <br /> -5 S Garage Frame-Wood Main 13 20 0 8 0 160.0 ft' 0 0.25 0.01 0 <br /> 6 W Garage Frame-Wood Main 13 21 9 8 0 174.0 ft' 0 0.25 0.01 0 <br /> DOORS <br /> # Omt Door Type Space S{onns U-Value Width Height Area <br /> Ft In Ft In <br /> 1 W Insulated Main None .46 2 8 6 8 17.8 ftz <br /> WINDOWS <br /> Orientation shown is the entered Proposed orientation. <br /> Wall Overhang <br /> # Omt 10 Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N 1 TIM Low-E Double Yes 0.65 0.35 N 30.00 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 2 E 2 TIM Low-E Double Yes 0.65 0.35 N 33.3 ft' 9 ft 4 in 0 ft 7 in None None <br /> 3 E 2 TIM Low-E Double Yes 0.65 0.35 N 9.0 ft' 1 ft 0 in 1 ft 0 in Drapesiblinds Exterior 5 <br /> 4 E 2 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 5 W 4 TIM Low-E Double Yes 0.65 0.35 N 20.0 ft' 9 ft 0 in 0 ft 7 in None None <br /> 6 W 4 TIM Low-E Double Yes 0.65 0.35 N 30.0 W 7 ft 0 in 0 ft 5 in Drapesiblinds Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 483.91 ft' 483.91 ft' 64 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ElA EgtA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 1654.8 90.85 170.85 .1303 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Duds <br /> 1 Electric Heat Pump/ Split HSPF:8.2 32.6 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit/ Split SEER:14 34 kBtu/hr 1133 cfm 0.75 1 sys#1 <br /> 3/6/2019 2:44 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.