Laserfiche WebLink
Manual S Com liance Re ort Job: R02191 C <br /> WC1917tSOft° p p Date: 03-06-19 <br /> Entire House By: AMA <br /> Bahrs Propane Gas&AC Inc <br /> 4441 Allen Rd,Zephyffils,FL33541 Phone:813-7825013 <br /> Project • • <br /> For: <br /> 5016 18th St,Zephyrhills,FL 33542 <br /> Cooling Equ 1pment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 25269 Btuh Entering coil DB: 80.4°F <br /> Outdoor design WB: 77.2'F Latent gain: 4875 Btuh Entering coil WB: 64.8°F <br /> Indoor design DB: 75.0°F Total gain: 30144 Btuh <br /> Indoor RH: 50% Estimated airflow: 1133 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment'type: SpIitASHP <br /> Manufacturer: 3 Ton-Franklin or Model: GSZ14036+ASPT37 <br /> Actual airflow: 1133 cfm <br /> Sensible capacity: 25500 Btuh 101%of load <br /> Latent capacity: 8500 Btuh 174%of load <br /> Total capacity: 34000 Btuh 113%of load SHR: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 20618 Btuh Entering coil DB: 69.1°F <br /> Indoor design DB: 70.0°F <br /> Manufacturers PeTfarmahce Data at Actual Design-Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: 3 Ton-Franklin or Model: GSZ14036+ASPT37 <br /> Actual airflow: 1133 cfm <br /> Output capacity: 32600 Btuh 158%of load Capacity balance: 32 'F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 'F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1133 cfm <br /> Output capacity: 10.0 kW 165%of load Temp.rise: 27 °F <br /> Meets all requirements ofACCA Manual S. <br /> -t'�i-wrighitsoft' 2019-Mar-0615:45:55 <br /> �. RightSuite®Universe]201818.0.32 RSU20773 Page 1 <br /> ACCA...ontmolin-Butterfield-5016 L-BR0219104.nry Cal=MJS Front Door faces: W <br />