ONEMOjetc.
<br /> PENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
<br /> Table Deck Application Type Description Page
<br /> 1A Wood New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6
<br /> 113 Wood New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-10
<br /> 1C Wood New,Reroof(Tear-Off),Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 11-14
<br /> 1D Wood New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 14
<br /> 1E Wood New,Reroof(Tear-Off),Recover C Mech.Attached Insulation,Bonded Roof Cover 15
<br /> 1F Wood New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15
<br /> 1G Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16
<br /> 1H Wood New,Reroof(Tear-Off),Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17
<br /> 2A Steel or Structural concrete New,Reroof(Tear-Off),Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 18-24
<br /> 213 Steel or Structural concrete New,Reroof(Tear-Off),Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 25
<br /> 2C Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 26-34
<br /> 2D Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1A Thermal Barrier with Vapor Barrier,Mech.Attached Insulation,Bonded Roof Cover 35
<br /> 2E Steel or Structural concrete New,Reroof(Tear-Off),Recover C-2 Bonded and Mech.Attached Insulation,Bonded Roof Cover 35
<br /> 2F Steel or Structural concrete New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 36-39
<br /> 3A Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 40-42
<br /> 313 Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 43-51
<br /> 3C Structural concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 52-53
<br /> 4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 54
<br /> 413 LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 55-58
<br /> 4C LWIC New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 58
<br /> 4D LWIC New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 59
<br /> SA CWF New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 60
<br /> 5B CWF New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 61
<br /> 5C CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 62
<br /> 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 63
<br /> 6B Gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 63-64
<br /> 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 64
<br /> 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 65
<br /> 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 66-73
<br /> 7B Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 74-89
<br /> NEMO-ETC,LLC Evaluation Report 01506.11.04-1120 for FL5680-R20
<br /> Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:04/02/2018
<br /> Prepared by: Robert Nieminen,PE-59166 GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 1 of 89
<br />
|