Laserfiche WebLink
ONEMOjetc. <br /> PENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE <br /> Table Deck Application Type Description Page <br /> 1A Wood New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 <br /> 113 Wood New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-10 <br /> 1C Wood New,Reroof(Tear-Off),Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 11-14 <br /> 1D Wood New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 14 <br /> 1E Wood New,Reroof(Tear-Off),Recover C Mech.Attached Insulation,Bonded Roof Cover 15 <br /> 1F Wood New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15 <br /> 1G Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16 <br /> 1H Wood New,Reroof(Tear-Off),Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17 <br /> 2A Steel or Structural concrete New,Reroof(Tear-Off),Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 18-24 <br /> 213 Steel or Structural concrete New,Reroof(Tear-Off),Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 25 <br /> 2C Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 26-34 <br /> 2D Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1A Thermal Barrier with Vapor Barrier,Mech.Attached Insulation,Bonded Roof Cover 35 <br /> 2E Steel or Structural concrete New,Reroof(Tear-Off),Recover C-2 Bonded and Mech.Attached Insulation,Bonded Roof Cover 35 <br /> 2F Steel or Structural concrete New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 36-39 <br /> 3A Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 40-42 <br /> 313 Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 43-51 <br /> 3C Structural concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 52-53 <br /> 4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 54 <br /> 413 LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 55-58 <br /> 4C LWIC New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 58 <br /> 4D LWIC New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 59 <br /> SA CWF New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 60 <br /> 5B CWF New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 61 <br /> 5C CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 62 <br /> 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 63 <br /> 6B Gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 63-64 <br /> 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 64 <br /> 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 65 <br /> 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 66-73 <br /> 7B Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 74-89 <br /> NEMO-ETC,LLC Evaluation Report 01506.11.04-1120 for FL5680-R20 <br /> Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:04/02/2018 <br /> Prepared by: Robert Nieminen,PE-59166 GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 1 of 89 <br />