My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21176
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21176
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 11:41:22 AM
Creation date
1/7/2020 11:41:20 AM
Metadata
Fields
Template:
Building Department
Company Name
ST ELIZABETH'S EPISCOPAL CHURCH
Building Department - Doc Type
Permit
Permit #
19-21176
Building Department - Name
ST ELIZABETH'S EPISCOPAL CHURCH
Address
5855 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OMEMO I etc. <br /> The following notes apply to the systems outlined herein: <br /> 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. <br /> Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. <br /> 2. Unless otherwise noted,fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: <br /> ➢ Wood: Drill-Tec#12 Fastener or Drill-Tec#14 Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation <br /> only),Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank <br /> embedment. <br /> ➢ Steel: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac <br /> Recessed Plate(insulation only);Drill-Tec ASAP 3S;Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate;Drill-Tec Extra Heavy Duty ASAP Roofing Fastener-Insulation. <br /> Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. <br /> ➢ Structural concrete: Drill-Tec#14 Fastener or Drill-Tec CD-10 with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only)or <br /> Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate. Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer's published <br /> installation instructions. <br /> 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA <br /> requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,Chapter 26,when installed with the roof cover. VersaShield°Solo—Fire-Resistant Slip Sheet may be used as a <br /> non-load-bearing,fire-barrier slip-sheet component within any system outlined herein. <br /> 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover), <br /> whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. <br /> Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified <br /> and/or FBC Approval documentation. <br /> 5. Preliminary insulation attachment for System Type D:Refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). <br /> 6. Unless otherwise noted,insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. <br /> ➢ Hot asphalt: Full coverage at 25-30 Ibs/square <br /> ➢ OMG OlyBond 500(OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. using PaceCart,SpotShot or Canister dispensers. Note: OlyBond Classic or OlyBond 500 <br /> Green may be used where OlyBond 500 is referenced. <br /> ➢ GAF LRF Adhesive M(LRF-M): Continuous 1-inch wide ribbons,12-inch o.c <br /> ➢ Millennium One-Step Foamable Adhesive(M-OSFA): Continuous 1-inch wide ribbons,12-inch o.c. <br /> ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. <br /> ➢ Note: When multiple loyers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. <br /> ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. <br /> 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum <br /> Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then <br /> the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. <br /> ➢ Hot asphalt: MDP -240.0 psf (Min.0.5-inch thick) <br /> ➢ OlyBond 500(OB500): MDP -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, <br /> EnergyGuard NH Ultra Polyiso Insulation) <br /> ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick EnergyGuard RH or RN) <br /> ➢ OMG OlyBond 500(OB500): MDP -485.0 psf (Min.0.5-inch thick EnergyGuard RA) <br /> ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): MDP -117.5 psf (Min.1.0-inch thick) <br /> 8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. <br /> NEMO ETC,LLC Evaluation Report 01506.11.04-1120 for FL5680-R20 <br /> Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:04/02/2018 <br /> Prepared by: Robert Nieminen,PE-59166 GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 2 of 89 <br />
The URL can be used to link to this page
Your browser does not support the video tag.