PGT Industries,Inc.
<br /> NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
<br /> A. DRAWINGS
<br /> 1. Manufacturer's die drawings and sections.
<br /> (Submitted under previous NOA No. 15-0519.05)
<br /> 2. Drawing No. MD-SH5500-01 titled "Single Hung Window Installation - LM", sheets
<br /> 1 through 13 of 13, dated 05115115, with revision B dated 06/06/17, prepared by
<br /> manufacturer, signed and sealed by Anthony Lynn Miller,P.E.
<br /> B. TESTS
<br /> 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
<br /> 2) Large Missile Impact Test per FBC, TAS 201-94
<br /> 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94
<br /> along with marked-up drawings and installation diagram of a PVC sliding glass door,
<br /> a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS
<br /> spacer system,Durasealo spacer system, Super Spacer®NXTT''I spacer system and XL
<br /> EdgeTm spacer system at insulated glass,prepared by Fenestration Testing Laboratory,
<br /> Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15,
<br /> 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega, P.E.
<br /> (Submitted under previous NOA No. 16-0714.03)
<br /> 2. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94
<br /> 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
<br /> 3) Water Resistance Test,per FBC, TAS 202-94
<br /> 4)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94
<br /> 5) Large Missile Impact Test per FBC, TAS 201-94
<br /> 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94
<br /> along with marked-up drawings and installation diagram of a series 5500 PVC single
<br /> hung window,prepared by Fenestration Testing Laboratory,Inc., Test Report No.
<br /> FTL-7964, dated 11/15/14, signed and sealed by Idalmis Ortega, P.E.
<br /> (Submitted under NOA No. 15-0519.05)
<br /> 3. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
<br /> 2)Large Missile Impact Test per FBC, TAS 201-94
<br /> 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
<br /> along with marked-up drawings and installation diagram of a series 5500 PVC single
<br /> hung window,prepared by Fenestration Testing Laboratory,Inc., Test Report No.
<br /> FTL-7966, dated 08/21/14, signed and sealed by Idalmis Ortega, P.E.
<br /> (Submitted under NOA No. 15-0519.05)
<br /> C. CALCULATIONS
<br /> 1. Anchor verification calculations and structural analysis, complying with FBC 51n
<br /> Edition (2014), dated 05/15/15 and 08/29/17,prepared by manufacturer, signed and
<br /> sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No. 15- 9.05
<br /> Manuel ere P.E.
<br /> Product Contro x iner
<br /> NOA No. 17-0630.05
<br /> Expiration Date: July 30,2020
<br /> Approval Date: November 30,2017
<br /> E-1