Laserfiche WebLink
ERD <br /> \-J TRINITY <br /> 6. INSTALLATION: <br /> 6.1 Mule-Hide TPO-c Single Ply Roof Systems shall be installed in accordance with Mu e-Hide Products Co., Inc, published <br /> installation instructions,subject to the Limitations/Conditions of Use noted herein. <br /> 6.2 System attachment requirements for wind load resistance are set forth in Apperdix 1. "MDP" = Maximum Design <br /> Pressure is the result of testing for wind load resistance based on allowable wind loa Js,and reflects the ultimate passing <br /> pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already ben applied). Refer to FBC 1609 for <br /> determination of design wind pressures. <br /> 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, rr embrane shall be installed running <br /> perpendicular to steel deck flutes. <br /> 7. BUILDING PERMIT REQUIREMENTS.- <br /> As required by the Building Officialgir Authority Having Jurisdiction in order to properly evaluz to the installation of this product. <br /> S. MANuFAcruRiNG PLANTS: <br /> Contact the noted QA agency for information on product locations covered to F.A.C.Rule 61G 0-3 QA requirements. <br /> 9. QUALITY ASSURANCE ENTITY: <br /> UL,LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com <br /> -THE I 8-PA GES THAT FOLLOW FORM PART OF THIS EVALUATION REP IR T- <br /> Exterior Research and Design,U.C. -valuation Report M15060.06.09-R3 <br /> Cerfffleate ofAuthorization#9503 FL12772-R3 <br /> Revision 3:03/18/2015 <br /> Page 4 of 4 <br />