My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21227
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21227
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2020 11:03:16 AM
Creation date
1/8/2020 10:32:43 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21227
Building Department - Name
CHIRNO JR,ROMELIO &JOHANNA
Address
6525 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
< r <br /> Enphase IQ 7 and iQ 7+Microinverters <br /> INPUT DATA-(VC) IQ7.60 2-US/IQ7-60.6-US I47PLUS-722-US/IQ7PLUS-72.8-US <br /> Commonly used module pairings, 235 W-350 W+ 235 W=440 W+ <br /> Module compatibility 60-cell PV modules only, 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V 60 V <br /> Peak powertracking voltage. 27 V-37 V 27.V-45 V <br /> Operating range- 16 V-48 V 16 V-60 V <br /> Min/Max start voltage 22 V/48 V 22 V/60 V <br /> Max DC shortcircuit current(module[so) 15 A '15 A <br /> Overvoltage class DC port 11 II <br /> DC port backfeed current 0 A 0 A <br /> PV array configuration Tx 1 ungrounded array;No additional-AC side protection required; <br /> AC aide protection requires max 20A per branch circuit <br /> OUTPUT DATA.(AC) IQ 7 Microinvorter " " IQ 7+Microinvertar <br /> Peak output power- -- M�250 VA ~ - 285 VA <br /> Maximum continuous cutput power 240 VA 290 VA <br /> Nominal(L-L)voltage/rangez 240 V/ 208V/ 24O V/ 208 V/ <br /> 211264 V 183-229 V 211264 V 183-229 V <br /> Maximum continuous output current 1.0 A'(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) <br /> Nominal.frequency 60 Hz 60 Hz <br /> Extended frequency range 47-68 Hz 47=68 Hz <br /> AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms <br /> Maximum units per 20 A(L-L)branch circuit" 16(240 VAC) 13(208 VAC) 13(240.VAC) 11(208 VAC) <br /> Overvoltage class AC port III iII <br /> AC port backfeed current O A 0 A. <br /> Power factor setting 1.0 1.0 <br /> Power factor(adjustable) 0.7 leading.,.0.7 tagging 0.7 loading...0.7 lagging- <br /> EFFICIENCY @240 V @208 V @240 V @208 V <br /> Peak CEO effrclency 97.6% 97.6% 97.5% 97 3% <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.6% <br /> MECHANICAL DATA- <br /> Ambient temperature range -40106 to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connector type(1Q7.-602-US&IQ7PLUS-722US) MC4(or AmphenolH4UTX with additional Q-DCC-5adapter) <br /> Connectortype(IQ7.60-8-US&107PLUS 72:8-US) Friends PV2(MC4 intermateable). <br /> Adaptors for modules with MC4 or UTX connectors: <br /> -PV2 to MCA:order ECA-S20-S22 <br /> -PV2 to UTX:order ECA470-925 <br /> Dimensions(WxHxD) 212 mm x 175 mm x 301 mm(without bracket) <br /> Weight 1.08 kg(2.38 ibs) <br /> Cooling Natural convection-No fens <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> .Enclosure Class li double-insulated,corrosion resistant polymeric enclosure <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor. <br /> FEATURES <br /> Communication "Power One Communication(PLC) <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options. <br /> Both options require installation of an Enphase IQ Envoy? <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the lead=break <br /> disconnect required by NEC 690. <br /> 'Compliance CA Rule 21(UL 1741-SA) <br /> UL 62109=4,UL1741/iEEE1547,FCC Part 15 Class B,ICES-0003.Ctass 8, <br /> CAN/CSA-C27-2 No.107.1=01 <br /> This product Is UL Listed as-PV Rapid Shut Down Equipment and cohfbnns with NEC-2014 and <br /> NEC 2017 section 690.12 and C22.1.2015 Rule 64416 Rapid Shutdown of PV Systems,for AC <br /> and DC conductors,when installed according manudacturees instructions. <br /> 1;No enforced OC/AC ratio.See the"compatibility calculator att)Ilpt1/enphaflP..Com re/Support -comoatihiifty <br /> 2.Nominal voltage range can be emended beyond nominal if required by the utility. <br /> 3.Limns may vary.Refer to local requirements to define the number of microlnvertera per branch In your area <br /> To leam more about Enphase offerings,visit.enphasexam G EN PHASE. <br /> .0 2018 Enphase Energy.All rights,reserved.All trademarks or brands used are the property of Enphase Energy,lnc <br /> 2018-os-24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.