Laserfiche WebLink
s 1 <br /> GrounDinG LUG inSTaLL <br /> s <br /> 4 <br /> Necessary Components: <br /> One of-the following ground lugs(or any UL 2703 compliant ground lug), <br /> Burndy CL50-1TN Ground Lug(UL 2703=E3513431 UL 467--E9999), <br /> ILSCO SGB4 Ground-Lug(UL 2703-E354420 /UL 467-E34440). <br /> ILSCO GBL4DST(UL 2703-E354420:/UL 467-E34440) <br /> ILSCO GBL-4DBTH(UL 27.03-E354420 [UL 467-E34440) <br /> ILSCO GBL-4SS(UL 2703 E354420 /UL 467-E34440) <br /> Note.Drill and deburr hole in.Ground Lug prior to installation <br /> 14 AWG-4 AWG Copper Ground Wire* Torque Values: <br /> 8 32 x 0S"Serrated Flange Head Solt(300 SeriesSS) 1+10 AWG=20 in-tbs. <br /> 8-32Serrated Flange Nut(300 Series SS). 8.AWG=25-in4bs. <br /> 11/3r and 1/4"wrenches or ratchets/sockets &4 AWG=351n4bs. <br /> 1 Insert the Range bolt into the module ground hole.Place Star.Washer over bolt.Place ground lug over the bolt and. <br /> Star Washer;and turn to desired orientation. <br /> 2 install Flange Nut. <br /> 3 Tighten Flange Nut/Bolt. <br /> 4 Place wine in Ground Lug channel and tighten setscrew to.complete-assembly. <br /> "Wire should.be sized in accordance with the National Electrical Code,ISIMA-7%Section 690.45,:and a minimum of <br /> 1 Wclearance required between bare capper wire and aluminum. <br /> Drill hole per grounding lug:manufacturers <br /> .specifications in the upsiope:part of Rock-it Coupling <br /> for attaching grounding lug. <br /> A- <br /> Note:Deburr!tole In Ground Lug anct Rock-it Coupling prior to installation. <br /> www ecofastensoleneDm lnfo@ecofimtensolar.com 877-859-3947 6 <br />