Laserfiche WebLink
12 3/4"MAX O.C.(TYP.) <br /> 6" MAX.(TYP.) SEE NOTE 2 WINDOW SYSTEMS <br /> 6" MAX.(TYP.) 1900 SW 44TH AVE. <br /> OCALA.FLORIDA 34474 <br /> WWW.CWS.CC <br /> INSTALLATION <br /> ANCHOR(TYP.) <br /> 1000 ALUM. <br /> GUARDIAN DOOR <br /> NON-IMPACT <br /> 17" <br /> MAX.O.C. ¢ z a z <br /> (TYP') f= 0w0 aWoo <br /> INSTALL TWO#8 ANCHORS THRU w z o z rc_z r-- <br /> STRIKE PLATE AND DEADBOLT STRIKE o F w§z O ft 3:_ <br /> PLATE INTO SUBSTRATE(TYP.) z z g a ir w oO O <br /> INSTALL ONE#8 ANCHOR THRU o0 ov cn of ti a�F-a <br /> EACH HINGE INTO SUBSTRATE(TYP.) z zz—?z z F>N <br /> U)a <ZVZOLLVWF- Z�OFO <br /> ; �FU Z'dQ WWO O W` a�OWA <br /> F z O1nl- <br /> o_ <br /> ,���i�llllll+ <br /> , <br /> ANCHOR LAYOUT .GQ9Nc9NSFGpyy. <br /> No 58201 •�9� <br /> ir <br /> OF :.40 <br /> NOTES: +n , to <br /> 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. <br /> 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING z�• <br /> SHIMS SHALL BECONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. <br /> 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/15/2017 <br /> LUCAS A.TURNER,P.E. <br /> 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED FL PE#58201 <br /> WOOD MUST BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. <br /> NORTH PORT,FL 34288 <br /> 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN PH.941-380-1574 <br /> THE MINIMUM SPECIFIED IN TABLE 1,SHEET 6. SHEET DESCRIPTION: <br /> 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHOR SCHEDULE AND <br /> NOTES <br /> 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONTRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: <br /> 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE ADE 09/QB/08 <br /> STRUCTURE.SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#. REV.: <br /> 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: ALE: 6 F <br /> FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS),FMA/AAMAANDMA 300(EXTERIOR DOORS) scA�E: SHEET <br /> 1:20 5 OF 6 <br />