My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21233
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21233
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2020 11:05:30 AM
Creation date
1/8/2020 10:36:16 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21233
Building Department - Name
RIVER LT,NATALIE MARIE & G T
Address
39607 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P . . R .T. ENGINEERING EXPRESS® <br /> PRODUCT EVALUATION REPORT <br /> ENGINEERING EXPRESS® <br /> EXPERT PRODUCT EVALUATION REPORT <br /> August 12,2017 <br /> Application Number: FL 15491.1-R4 <br /> FLB Project Number: 15-2409a <br /> Product Manufacturer: Structall Building Systems <br /> Manufacturer Address: 350 Burbank Road <br /> Oldsmar,FL 34677 <br /> Product Name&Description: EPS Foam Core Roof Panels-Metal Skin <br /> (HVHZ and Non-HVHZ) <br /> Scope of Evaluation: <br /> This Product Evaluation Report is being issued in accordance with the requirements of the Florida <br /> Department of Business and Professional Regulation(Florida Building Commission)Rule Chapter 61G20- <br /> 3.005, F.A.C.,for statewide acceptance per Method 1(d). The product noted above has been tested <br /> and/or evaluated as summarized herein to show compliance with Florida Building Code Sixth Edition <br /> (2017)and is,for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of <br /> this product shall be required following pertinent Florida Building Code modifications or revisions. <br /> Substantiating Data: <br /> • PRODUCT EVALUATION DOCUMENTS <br /> FLB drawing#15-2409a titled"EPS Foam Core Roof Panels-Metal Skin", sheets 1-3,prepared by Frank <br /> L. Bennardo, P.E., Inc.,signed&sealed by Frank L. Bennardo, P.E. Is an Integral part of this Evaluation <br /> Report. <br /> r <br /> TEST REPORTS <br /> Uniform static structural performance has been tested In accordance with ASTM E72-98&E72-05 test <br /> standard per test report(s)#506027-B, 506027-C, 506027-D, 509014-A, 509014-B(signed by Rick <br /> Cavanagh)by Terrapin Testing, Inc., in addition to test report(s)#ESP01 2351 P-1,#ESP01 2351 P-2, <br /> #ESP012351 P-3,#ESP012351 P-3A,#ESP012351 P-4,#ESP012351 P-5,#ESP012351 P-6, <br /> #ESP012351 P-6A,#ESP012351 P-7,#ESP012351 P-8,#ESP012351 P-9,#ESP012351 P-9A(signed by <br /> Ramesh Patel, PE)by Element Materials Technology. <br /> Thermoplastic structural performance for self-Ignition temperature has been tested in accordance with <br /> ASTM D 1929 per test report VTEC#100-1137-1 (signed by Neil Schultz)by VTEC.�pAgr#pjies Inc.,with <br /> an approved self-ignition temperature greater than 650OF as ���� ��•i <br /> required per FBC Section 2606.4. Rai `. . if#�for <br /> Thermoplastic structural performance for surface burning Ra � through". <br /> ` f <br /> characteristics have been tested in accordance with ASTM E-84 <br /> per test reports 15328-97939(aluminum skin EPS panels)and 1���++ <br /> 15328-97938(steel skin)1 (signed by William E. Fitch,'PE)by <br /> U1,7- 5: 07 <br /> Omega Point Laboratories.The roof assembly was tested as a 3" <br /> thick panel(for aluminum skin)and as a 4"thick panel(for steel F. t3enr®7dM PEE. . <br /> skin EPS panels)with an approved smoke developed index not �9.pi . <br /> 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORI A $. . 2 <br /> PHONE: (954) 354-0660 - FAX: (954) 354-0443 <br /> ENGINEERINGEXPRESS.COM <br /> Y.VWA=M1NM ff8FQMCM ROOF PANM-M-UPME FLOW FORMN ROROA MM 4MAOMPMI FN UM%1E11E•240Y,4VAL- t61M.1000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.