23..Tamper- Resistant.Receptacles in accordance with 406.11 Of the 2016 NRC <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 26. R403.5.3Hof water pipe insulation <br /> Insulation for hot.water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping-1;inch (19.1 mm)and larger in nominal diameter.. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space:, <br /> Piping from the water heater to:a distribution manifold: <br /> Piping:located under a floor slab. <br /> Buried-in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the energy cacls-shall be with permit at all times <br /> 27. Copy of-ttnal.'insulation report shall-be provided ivith permit before r1nal <br /> 28 No fence,pool or screen enclosure :is-issued with Ihis permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />