My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21296
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21296
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 11:44:19 AM
Creation date
1/8/2020 11:44:17 AM
Metadata
Fields
Template:
Building Department
Company Name
OAK RUN PROPERTIES INC
Building Department - Doc Type
Permit
Permit #
19-21296
Building Department - Name
OAK RUN PROPERTIES INC
Address
37757 37765 OAKRUN CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TAMKO BUILDING PRODUCTS <br /> CREEKAsphalt Shingles <br /> TECHNICAL SERVICES, LLC <br /> LIMITATIONS <br /> 1) Fire Classification is not within the scope of this evaluation. <br /> 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads <br /> established for components and cladding and in accordance with FBC requirements. <br /> 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. <br /> 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. <br /> 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck <br /> shall be checked for protrusion and corrected prior to underlayment application. <br /> 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the <br /> deck. <br /> 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's <br /> published application instructions. Where discrepancies exist between these sources, the more restrictive <br /> and code compliant detail shall prevail. <br /> 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with <br /> Rule 61 G20-3. <br /> COMPLIANCE STATEMENT <br /> The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building <br /> Code, 6`h Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. <br /> `o'°°°°Pp,Y <br /> GENS• �s 2017.09.25 <br /> No 74021 = <br /> 12W5 11 :31 :41 <br /> = = 04'00' <br /> . :• STATE OF <br /> 0 <br /> •'•iOj 4P•'���.` Zachary R. Priest, P.E. <br /> R, Florida Registration No.74021 <br /> S,fill <br /> 0NAe Organization No.ANE11669 <br /> CERTIFICATION OF INDEPENDENCE <br /> CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing <br /> products under this evaluation. <br /> CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under <br /> this evaluation. <br /> Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products <br /> under this evaluation. <br /> Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the <br /> product. <br /> END OF REPORT <br /> TBP15001.4 FL18355-R4 Page 11 of 11 <br /> This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK <br /> Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. <br /> This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not <br /> specifically addressed herein. <br />
The URL can be used to link to this page
Your browser does not support the video tag.