• Company: REECE BUILDERS Job Description: 5 WINDOWS <br /> Prepared By: TOM <br /> Client Name: LAURIE Project Number: 13353 <br /> DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING <br /> Design Data Building Data <br /> Wind Velocity(mph) 145 Mean Roof Height 18 <br /> Risk Category 2 Building Width(ft) 46 <br /> Exposure Category B Building Length(ft) 30 <br /> Directionality Factor+/- 0.85 Roof Slope (x:12) 4 <br /> Internal Pressure Coefficient 0.18 <br /> Design pressures listed below are: Allowable Strength <br /> OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE <br /> MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) <br /> 1 WINDOWS 5 3 36 50 22.4 -29.7 <br /> 2 W 5 3 36 50 22.4 -29.7 <br /> 3 W 4 3 73 50 21.3 -23.2 <br /> 4 W 4 3 36 37 22.7 -24.6 <br /> 5 W 4 3 73 50 21.3 -23.2 <br /> Width of End Zone(a)in feet= 3 <br /> 5 h <br /> 4 0 <br /> _ Y I <br /> " Y <br /> STRUCTURES INTERNATtONAL,LLC <br /> _PraYa!»p Sim�6 ':xis 3v Ccsrshext€rns` <br /> 4/11/2019 9:09 AM <br />