My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21318
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21318
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2020 11:16:54 AM
Creation date
1/8/2020 1:34:28 PM
Metadata
Fields
Template:
Building Department
Company Name
TACO BELL
Building Department - Doc Type
Permit
Permit #
19-21318
Building Department - Name
TACO BELL
Address
7313 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Encon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: Encon Services, Inc. <br /> Taco Bell P.O. Box 3613 <br /> 7313 Gall Blvd Apollo Beach, FL 33572 <br /> Zephyrhills, FL 813-655-3373 <br /> 3'-0"x 3'-4"Medium Swing Bell F 813-655-9814 <br /> Design-per Florida Building Code, 6th-Edition(2017)Section 16 Wind Load <br /> ASCE 7-10, Load Case: D+0.6W Aaron Biedenbach, P.E. <br /> Design Specifications FL PE#52949, FL EB 9394 <br /> Risk Category II OH PE 60756, OC#01893 <br /> Kzt 1 KY PE #20281, P#2463 <br /> Exposure Factor C IN PE#PE 19600332 <br /> Kd 0.85 FL CBC#060535, QB#22527 <br /> Kz <br /> 0 <br /> V 40 (mph) 0`_p• ���®��� <br /> GCp-GCpi 1.1 Zone 4, H<60 Feet <br /> Wind Pressure 46.0 (psf) LICENSE q� <br /> #52949 <br /> Sign Information <br /> Height 3.00 (ft) STATE OF <br /> Width 3.30 (ft) <br /> Thickness 0.25 (ft) ��. FC0R�pP <br /> Distance grade to top 30 (ft) <br /> .Wind Shear Force 20.69 (lb) <br /> Weight of Sign 99 (lb) DATE SIGNED: <br /> Total Shear Force = 101.14 (lb) 4/9/2019 <br /> Total Tension Force = 273.10 (Ib) <br /> Required Provided <br /> Fastener size(Nominal) 3/8 3/8 <br /> Minimum number of fasteners 4 4 <br /> Shear Force per fastener(lb) 25.3 280 <br /> Tension Force per fastener(lb) 68.3 352 <br /> Combination Tension and 0.28 <1 O.K. <br /> Sheer ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3'EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 5/8'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-1/2'EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/2'EMBEDMENT) <br /> CMU,SOLID CONCRETE,BRICK IHILTI HIT ROD W/HY-20 ADHESIVE(31/2'EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 4/9/2019 <br /> Taco Bell Zephyrhills 3-0 x 3-4 Medium Swing Bell <br />
The URL can be used to link to this page
Your browser does not support the video tag.