Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 2605 Elev J Builder Name: DRH Express Homes <br /> Street: �q`72 5111"ad� 044'161 46-tud Permit Office: <br /> 10 <br /> City,State,Zip: Zephyrhills,FL, �� �✓ Permit Number: <br /> Owner: �C Jurisdiction: <br /> Design Location: FL,Tampa `-�J County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2389.10 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 314.89 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 11.Duct <br /> c. R= ft2 <br /> s R ft2 <br /> 7. Windows(252.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 212.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.208 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.097 Total Proposed Modified Loads: 86.41 PASS <br /> Total Baseline Loads: 86.20 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 114E S�� <br /> this calculation are in compliance with the Florida Energy specifications covered by this -"v l T;` 0, <br /> Code. calculation indicates compliance ';, <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> DATE: 1-23-1`1 this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. , <br /> with the Florida Energy Code � 0 WTI <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: j <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ! <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. <br /> 1/23/2019 12:58 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 <br />