Laserfiche WebLink
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: ) Permit#: <br /> I.Jot:lnformation�• - - <br /> Builder: DRH Express Homes Community: Lot: 55/6 <br /> Address: <br /> City: Zephyrhills State: FL Zip: <br /> 141C'Leakage',Tes_t;,Res.ultsl Pa"ssing,results:must'meet'eitlieahe Peff4rmance,•.P�escr�ptive;orERGllilg[hod . <br /> -r• <br /> �jp <br /> ESCRII?TIVi,METHOD?The 6uildin'or.dwellin?unit stialf6eaesteel and;verifieii•:as Fjagiii:an'air lea Rap,fatg;of'nofiexceeding:7 air <br /> cli'an es:'erfiouf,:af,`a''ressu�ecof;0:2`iricfi w: 50:Pascals inEClirriafe Zones 1.and2; 1j <br /> ...-77 _ _ _ _ -_ <br /> ceedin" <br /> �. PERFORMANCE=of,ERI;METHOD_-1 he:6uildin or;dwellin sliall be;tested ari8..verified_as fiaving an:air leakage'raf`e".of <br /> .�, 9 9 <br /> ttieselectedACH(5 vluw 5 e) R , tm rf m 50! <br /> :,ACH(50)'spe'cified on.Form R405=201.7-Energy{Calc(Performance)lor='R406`20.17(ERI)` ; 7.000 <br /> x 60 _ 22630 — Method for calculating building volume: <br /> CFM(50) Building Volume ACH(50) O Retrieved from architectural plans <br /> 1-1 PASS 0 Code software calculated <br /> When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> i:Testind Company <br /> - - - - <br /> Company Name: _ Phone: <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 1/23/2019 12:59:13 PM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />