Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water'pipe insulation <br /> Insulation-for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping-1.inch (19.1 mm)and larger in nominal diameter. <br /> Piping.serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:water heater to.a distribution manifold. <br /> ,Piping.located under a floor slab. <br /> Buried in piping.. <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.Oe <br /> 26. A copy of the enemy cacls shall be.with permit at all times. <br /> 2 Z.Copy of final insulation-report shall be provided with permit before rinaL <br /> 28. No.'fence,pool onscreen enclosure .is issued with:this permit' <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />