Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots_ .shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> insulation for hot water. pipe with a minimum thermal resistance (R3-value) of R-3 shall be applied to the <br /> following: <br /> Piping V4 inch (19.1 mm)and larger in.nominal diameter. <br /> Piping:serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the.water heater to a distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower.door test shall be provided before C.O: <br /> 26. A cony of the energy cacls shall be with permit at all times. <br /> 27.:Copy oftinal insulation report shall be provided with Permit before fnaL <br /> 28. No Awe,-pool or'screen enclosure :is issued with:this.permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />