Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation Residential Performance Method <br /> Project Name: 2606A sf ADS Carrier.VW Builder Name: Lennar Homes 0802 <br /> Street: 6328 Cobble Bliss Street Permit office: City f Zephyrhills <br /> City,State',Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 380.00 ft <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ . <br /> 10.Ceiling Types (2576.0 sqft.) Insulation Area. <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 2576 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 11.Du cctt c.N R= ftZ <br /> s R ft? <br /> 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515:2 <br /> a. U-Factor: Dbl,U=0.33 159.00 ftZ <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.58 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency . <br /> SHGC: SHGC=0.32 a.Central Unit 35.0 -SEER:15.50 <br /> c. U-Factor: Dbl,U=0.33 16.00 ftZ <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency . <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area:Weighted Average Overhang Depth: 1.372 ft. <br /> Area Weighted Average SHGC: 0.245 14.Hot water systems <br /> a.Electric Cap:40 gallons . <br /> 8. Floor Types.(2576.0 sqft.) Insulation Area <br /> EF:0.950 <br /> a.Slab-On-Grade Edge,Insulation R=0.0 2576.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 70.71 w C c <br /> Glass/Floor Area: 0:083 ASS <br /> Total Baseline Loads: 73.00 <br /> .I hereby certify that the plans and specifications covered by - Review of the plans and <br /> this calculation are in.compliance.with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. ti r�r,+ � ;° . .+ „ O <br /> ')ave lal _ <br /> PREPARED BY: ��� Before construction is completed r <br /> DATE: this building will be inspected for O -1 <br /> compliance with Section 553.908 * a <br /> I herebycertify that this building,as designed, is in compliance Florida Statutes. <br /> fY 9� 9 <br /> with the Florida Energy Code. O!7 y{ <br /> OWNER/AGENT: BUILDIN FICIAL- <br /> DATE: DATE:. <br /> =:'Compliance requires certification.by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> Compliance requires an Air.Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00:ACH50(R402.4.1.2). <br /> Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn.for whole house. <br /> 1/15/20191:05 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Pagel of 4 <br />